Software
116 • Crestron SIMPL Windows
To save the contents of the IP Table editor to a file, select Save to Disk, browse to
the desired directory, name the file and click Save. To retrieve IP Table data that has
been saved to disk, click Load from Disk, browse to the file and click Open.
To upload the IP Table to the control system, click Send IP Table to Control
System.
Whenever an IP Table is sent to the control system, whether it is the "default" IP
Table created in Configuration Manager or the IP Table created in Viewport, it will
overwrite the previously loaded IP Table.
Set TCP/IP Console Password
The TCP/IP console password restricts TCP/IP access to the control system. The
password can be set using either an RS-232 or TCP/IP connection. Simply enter the
password in the New Password field and then re-enter the password in the Verify
field.
Click Disable Password to allow unrestricted access to the control system.
Set Network ID
The Set Network ID command is used to change the Net IDs of certain network
devices. Not all Net IDs can be changed in this way; some devices have different
hardware settings, and some touchpanels must be configured locally. Refer to the
hardware manual of the device to verify whether its Net ID can be changed using
Viewport.
As Viewport detects network devices, those devices will be listed in Current
Network Devices. The information given here includes the current Net ID of the
device, the type of device and its firmware version. Click Search for Devices to
refresh this list if any devices are added or removed from the network. To change the
Net ID select the device, choose a Net ID from the drop-down list, and then click Set
ID.
To send the Set ID command directly to a single device, click the Broadcast to All
ID's check box and connect only that device to the network. Select a new ID as just
described, and click Set ID.
Set Transmitter ID
Use Set Transmitter ID to change the ID of an infrared (IR) transmitter. This
requires a CNIDC (IR probe).
First enter the two-digit hexadecimal ID that the transmitter will be set to and click
OK. Position the IR probe of the CNIDC over the sensor on the transmitter and click
OK to begin programming. Continue to hold the IR probe in position until the LED
indicator on the transmitter stops flashing.
To verify the new ID, click Identify Transmitter ID on the Viewport Diagnostics
menu.
Set RFGWX Channel
The Set Channel command sets the radio frequency (RF) channel of a CNRFGWX
(two-way transceiver for STX Spectrum touchpanels) and STRFGWX (two-way
transceiver for the STX-1550C touchpanel). Each transceiver in a system requires a
unique hexadecimal RF channel; Crestron provides 16 channels ranging from 00 to
0F.
Crestron SIMPL™ Windows