Installation
RISK OF FIRE/ EXPLOSION
• This heater should not be used in potentially explosive atmospheres.
• Do not use in areas where gasoline, paint, or flammable liquids are used or stored.
• Installation minimum clearances specified in this manual must be followed.
• The heater must be installed in accordance with the manufacturer's installation instructions.
Minimum Clearances
This appliance must only be used in a well ventilated area. The heater should not be installed:
•
Where heat ignition can cause damage to gas cylinders/lines.
•
Near other combustible materials.
•
In open locations subject to harsh weather elements such as rain or snow.
Heater should be installed to allow adequate:
•
Clearance around air openings to combustion chamber.
•
Clearance from combustible material.
•
Provisions for accessibility and clearance for combustion and ventilating air supply.
Figure 2 shows the required clearances around the heater. All dimensions shown are minimum values.
Figure 2
20"
500 mm
10
40"
1016 mm
Heater width:
25 1/2"
650 mm
40"
1016 mm
79"
2000 mm
12"
300 mm
with optional
accessory
DGRSHIELD
(sold separately)