Download Print this page

Dimplex DGP Series Installation Instructions

Glass panel heater dgp series;

Advertisement

Quick Links

Glass Panel Heater
DGP Series

Important InstructIons

When using electrical appliances, basic precautions should always
be followed to reduce the risk of fire, electric shock, and injury to
persons, including the following:
1.
Read all instructions before using this appliance.
2.
The wall bracket supplied with the appliance must be used.
 W ArnInG: This heater is hot when in use. To avoid burns, do
not let bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, and curtains
at least 3 feet (0.9 m) from the front of the heater.
3.
Extreme caution is necessary when any heater is used by
or near children or invalids and whenever the heater is left
operating and unattended.
4.
Do not use this heater in the immediate surroundings of a bath,
shower, pool or other water basin.
electrical and building codes for minimum clearances from
electrical switches and circuits before installing this unit.
5.
If the heater is installed in a room containing a bath or shower,
it must be installed in such a way that all controls are out of
reach of a person using the bath or shower.
6.
Do not use outdoors.
7.
A heater has hot and arcing or sparking parts inside. Do not
use it in areas where highly flammable substances are used
(e.g. solvents, etc.) or stored.
8.
To prevent a possible fire, do not block air intakes or exhaust
in any manner. Do not use on soft surfaces, like a bed, where
openings may become blocked. Do not place material or
garments on the heater, or obstruct the air circulation around
the heater, for instance by curtains or furniture, as this could
cause overheating and a fire risk.
9.
Do not insert or allow foreign objects to enter any ventilation or
exhaust opening as this may cause an electric shock or fire, or
damage the heater.
10.
Use this heater only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electric
shock, or injury to persons.

SAVE tHESE InStruCtIonS

Figure 1
A
150
Min.
Model(s)
Volts
208 / 240
DGP1000-B
208 / 240
1.125 kW / 1.5 kW
DGP1500-B
208 / 240
1.5 kW / 2.0 kW
DGP2000-B
Check and observe all local
300 Min.
565
150 Min.
Watts
A (Figure 1)
0.75 kW / 1 kW
700 mm / 27.6"
770 mm / 30.3"
840 mm / 37.0"

Installation Instructions

Electrical Connection

Verify that the supply voltage is the same as that stated on the
heater (A.C supply only).
This heater is designed for use on a 208/240V 60Hz AC single-
phase supply. Connection requires a supply wire that must consist
of two wires plus ground and have a rating capable of handling all
loads on the circuit.
Make all relevant electrical connections within an installed
junction box and ensure all wiring meets all local electrical and
building codes. Where local code requires the disconnection of all
ungrounded supply lines, a double pole isolating switch must be
fitted to facilitate isolation.
Connection to the heater should be made using the provided fitted
cable clamp assembly at the back of the heater to meet local code
requirements.
WArnInG: Always use a qualified and licensed electrician for
all wiring and electrical connections. Improper wiring could lead
to a fire hazard.
Wall Mounting
!
IMPortAnt: The wall bracket supplied with the appliance
must be used. The heater should be positioned observing the
minimum clearances stated around the heater (Figure 1).
WArnInG: Do not locate the heater immediately below a fixed
socket outlet or connection box.
1.
Remove wall mounting bracket from the back of the heater by
depressing the spring latch at the top of each bracket (Figure
2).
2.
Fix the wall bracket securely to the wall through the four (4)
screw holes provided.
3.
Present the heater to the wall bracket and engage lower slots in
the back with bracket.
4.
Raise the heater to upright position and push the heater onto
bracket to engage top latch.
Figure 2
shelf
B
C
GFP500
390
GFP750
390
GFP1000
560
GFP1500
630
GFP2000
800
B (Figure 1)
C (Figure 2)
107 mm / 4.25"
560 mm / 22"
107 mm / 4.25"
630 mm / 24.8" 300 mm / 11.8"
107 mm / 4.25"
800 mm / 31.5" 300 mm / 11.8"
D
D
D
E
255 Min.
300
300
300
300
300
D (Figure 2)
E (Figure 2)
300 mm / 11.8"
255 mm / 10" MIN
255 mm / 10" MIN
255 mm / 10" MIN
C
C
Weight
14.8 kg / 32.6 lbs.
16.4 kg / 36.2 lbs.
19.5 kg / 42.9 lbs.
7210370100R01
INDGCAP7RG

Advertisement

loading

Summary of Contents for Dimplex DGP Series

  • Page 1: Important Instructions

    Glass Panel Heater DGP Series Important InstructIons Installation Instructions Electrical Connection When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to Verify that the supply voltage is the same as that stated on the persons, including the following: heater (A.C supply only).
  • Page 2 Any claims under this warranty must be submitted in writing to: the event that the product overheats for some reason, the cut-out Dimplex North America Limited, 1367 Industrial Road, Cambridge Ontario, prevents excessive temperatures on the product by cutting the N1R 7G8, Canada.

This manual is also suitable for:

Dgp1000-bDgp1500-bDgp2000-b