Quick guide - RetroSign GR1 & GR3
Getting started
Turn the RetroSign on by pressing.
instrument. Repeat
The instrument is calibrated and ready if the
first be calibrated. Press
Start a measurement by pressing the trigger knob.
measuring then the measured values is shown.
If errors are detected during a measurement or calibration sequence, a message will be displayed
and one or more error icons appear.
Keyboard functions:
On/Clear
Off
Scroll up
Scroll down
Calibration
Enter
Trig
Icons:
The instrument status and operational mode are signalled by the use of icons.
Instrument is calibrated and ready.
Menu selected.
Calibration selected.
Reference calibration in progress.
Zero calibration in progress.
RFID function enabled.
GPS On. Position FIX OK
Calculating mean values
GR3 & GR1 Quick Guide (UK) rev 26-3-2009.doc
The display will show some information about the
to show the results of the last measurement.
icon is displayed, if not, the instrument must
and follow the instructions to do this.
Push shortly to activate the instrument.
When switched on it clears all selected operations.
Displays the last measurement result.
Clears the mean calculation when displaying this
Terminates all activity, saves changed values and powers off.
Open the menu, scroll through menus
Increment/scroll edit values.
Open the menu, scroll through menus
Decrement/scroll edit values.
Open Instrument calibration menu, select/change settings.
Activate selected function or accept changed settings.
Switch between the different results and status display
screens
Start R' measurement.
Start quick calibration.
(option)
(option)
®
The display shows "WAIT" while
Calib. Monitor Active for normal aperture.
Calib. Monitor Disabled for reduced aperture.
Battery fully charged.
Battery getting low.
Battery empty, recharge.
Display backlight is enabled.
GPS On. No FIX
(option)
Bluetooth Disconnected/Connected
(option)

Advertisement

loading

Summary of Contents for Delta RetroSign GR1

  • Page 1 ® Quick guide - RetroSign GR1 & GR3 Getting started Turn the RetroSign on by pressing. The display will show some information about the instrument. Repeat to show the results of the last measurement. The instrument is calibrated and ready if the icon is displayed, if not, the instrument must first be calibrated.
  • Page 2 Calibration: RetroSign features two levels of calibration: quick and full. Quick calibration. Quick calibration is initiated by first pressing and then the trigger. Mount the reference cap (reflective surface pointing in) before triggering. The instrument will be calibrated to the last used values.