17
HEAT / COOL SETPOINT DIFFERENTIAL
The Heat/Cool temperature differential prevents the
heating setpoint from being set above or too close to
the cooling setpoint, resulting in inadvertent cycling
between heating and cooling.
Press the
NEXT
key to select
Up
or
Down
key to set the setpoint differential.
Option
CANCEL
Option 10
and press the
Set To
NEXT
ENTER
18

FIRST STAGE DIFFERENTIAL

First stage temperature differential determines the
sensitivity of the thermostat. A lower differential will
cause the thermostat to cycle more often with smaller
temperature swings.
If the temperature differential between indoor
temperature and setpoint temperature is greater than
the first stage temperature differential, first stage heating
or cooling will be activated.
Press the
NEXT
key to select
Up
or
Down
key to set the first stage differential.
Option
CANCEL
Option 11
and press the
Set To
NEXT
ENTER
15