5. Other Maintenance – Periodic Descaling of the Water Reservoir
NOTICE: Cleveland Range recommends that only qualified Cleveland Range authorized technicians
or trained onsite maintenance personnel perform this service.
a. Is Descaling Necessary?
1. Although, a SteamChef should not normally require descaling, the use of "hard" water or
failure to follow the vinegar cleaning procedures in Chapter 6 may cause the accumulation of
scale in the SteamChef.
2. Scale can deposit in the bottom of the SteamChef reservoir and/or in its drain. Descaling can
help prevent a costly service call if scale buildup begins to impair the SteamChef's operation.
3. Descaling is not normally required on a SteamChef. Frequency will depend on the local water
quality, and the frequency of shutdown and cleaning of the water reservoir as described in
Chapter 3.
4. The frequency of descaling must be determined by the owner and performed by qualified
Cleveland Range authorized technicians, or trained onsite maintenance personnel.
b. If descaling is necessary, Cleveland Range recommends the use of DISSOLVE® Descaler Solution,
Cleveland Range Part No. 106174. No other system of descaling should be used.
Note: Part No. 106174 is the Part No. for a case (6 1-gallon containers) of DISSOLVE® descaler.
c. Call Cleveland Range at 216-481-4900 or 1-800-338-2204 if any questions arise.
d. To descale the SteamChef 22CGT3 and 22CGT6:
The liquid solution in Cleveland Range Descaler Solution Part No. 106174 can be harmful if not handled
properly. Follow these basic safety rules for handling and using this product. Instructions and warnings
on container labels supercede all other warnings and instructions.
Wear protective clothing when mixing or applying chemical cleaners
Wear rubber gloves, and OSHA approved eye protection when descaling
Avoid breathing fumes
If liquid contacts skin: wash with soap and water
If chemical contacts eyes: flush with water and seek medical attention
If chemical is swallowed or ingested: drink 1 or 2 glasses of water and seek medical attention
DANGER!
FAILURE TO DO SO CAN CAUSE DEATH OR INJURY
18