3. To Reset the High Limit Lockout:
IMPORTANT: Do NOT add water to cool the SteamChef. This causes equipment damage.
a. Turn OFF the ON/OFF lever.
b. Open the cooking compartment door and wait for the SteamChef to cool.
c. After the SteamChef is cool, check that the Water Level Sensor probes are clean.
d. Press the High Limit Reset Button located on the bottom of the appliance about 3 inches from
the control side and 4 inches from the front side. See Figure 3-4
If the button stays down, the SteamChef is cool enough to operate. Go to e).
If the button does not stay down, wait 5 more minutes and press it again.
1) If the button stays down, go to e).
2) If the button does not stay down, go to f).
e. Replace the control side cover and restart the SteamChef. See "Power On" in Chapter 3.
f.
If the High Limit Lockout repeats:
1) Replace the control side cover.
2) Follow the Shutdown Instructions in Chapter 3.
3) Call your qualified Cleveland Range authorized service representative.
Figure 3-4
Reset Button Location