Commands And Responses - Omron ZS Series Communication Command Reference

Zero smart sensor
Hide thumbs Also See for ZS Series:
Table of Contents

Advertisement

7
Example 2: To set the peak hold mode for the 1CH controller, assign a command as follows:
[Data No.]=02h, [Unit No.]=2Dh, [Machine No.]=01h, [Data to be written]=00000001h
MRC
SRC
02h
02h

Commands and Responses

Command
Parameter Type
MRC
SRC
"02"
"02"
2 bytes 2 bytes
Number of
Data to be written
elements
"8001"
4 bytes
Elements
Parameter Type
Writing start address
Number of elements
Data to be written
Parameter Type
Writing start
address
C002h
2D01
Reading start
address
4 bytes
4 bytes
4 bytes
Specify parameters depending on the data to be written.
List of Parameter Area Writing Commands page 2-6
Specify the Machine No. (=CH No.) of the controller to write data by using
an ASCII code expressed in hexadecimal numbers.
Please note that the format of "processing unit data writing" commands is
XXYYh (XX : <Unit No.>, YY : <Machine No.>)
About Channel No. When Controllers are Gang-mounted
page 1-2
Unit No. and Parameter No. page 3-4
Specify number of elements depending on the Parameter Type.
List of Parameter Area Writing Commands page 2-6
Data to be written is specified by using an ASCII code in hexadecimal
numbers.
Data length varies depending on commands.
・List of Parameter Area Writing Commands page 2-6
・Do not issue commands other than specified parameter
types. Issuing wrong commands may rewrite internal
parameters. In the case that internal parameters of
connected sensors are rewritten, execute "EEPROM
initialization" of operation instruction commands.
Connections and settings of external devices
Writing Parameter Areas
Writing parameter areas
Number of
elements
8001h
Details
CompoWay/F Communication Command Reference
Section 2
Data to be written
00000001h
2-7
ZS Series