Section 2
About General Information of Communication Commands
Writing Parameter Areas
Response
MRC
SRC
Response Code
"02"
"02"
2 bytes 2 bytes
Elements
Response Code
Response code for normal end
Response Code
"0000"
Normal end
Response code when an error occurs
Response Code
"1001"
Long command length
"1002"
Short command length
"1003"
Inconsistent number of
elements/data
"1100"
Parameter error
"1101"
Area type error
"1103"
Start address outside of
range error
"1104"
End address outside of
range error
"2203"
Operating error
"2204"
Operating error
"2205"
Operating error
ZS Series
2-8
CompoWay/F Communication Command Reference
4 bytes
Indicates controller status for the command.
Name
No errors.
Error name
Command length is too long.
Command length is too short.
Number of elements and data do not match.
Data to be written is out of specified range.
Parameter type is wrong.
Writing start address is out of range.
Writing start address specifies the sensor of the
unconnected Machine No.
Specified number of elements is other than "8001."
Setting is abnormal.
Refer to the User's Manual of the ZS Series for
setting error conditions of thresholds and the
hysteresis width.
Operating mode of sensor is other than RUN.
Invalid command.
Details
Details
Cause