8.3.1
Mobile Home
It is strictly forbidden to install a unit with a single wall pipe in a mobile home.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
6" (152 mm)
B
15" (381 mm)
C
5" (127 mm)
L
84" (213 cm)
A
B
E
CAN
48"
122 cm
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
7
above mentioned.
Page 48
USA
6" (152 mm)
15" (381 mm)
5" (127 mm)
84" (213 cm)
D
48"
US
Flush
36"
92 cm
DISTANCES
WITH DOUBLE WALL PIPE CONNECTOR
Canada
D
9" (229 mm)
E
24.75" (629 mm)
F
15" (381 mm)
F
Installation and operation manual - Bistro woodburning cookstove
FROM PIPE CONNECTOR
7
USA
9" (229 mm)
24.75" (629 mm)
15" (381 mm)
C
F