4-2. Contrast Setting
The LCD contrast can be set.
Procedure:
1. Enter the test mode.
(Refer to "1. SETTING THE TEST MODE" on page 51)
2. Press the [
DPC]/[ A-B
v
Setting".
Test mode menu screen
Version
Contrast Setting
LCD LED Light
Sleep
OFF DeepSleep
Power Down
Key Count
HotPlug Count
Log
3. Press the [
] button to display the LCD contrast setting screen.
N
(Displayed values in the following fi gure are example)
Screen display
NAME :
24
SAVE : Play
Button input settings under this mode of operation:
[
] : Contrast value down
.
[
] : Contrast value up
>
[
] : The current contrast value is set (saved)
N
4. Press the [
] button to complete the contrast value setting,
N
"Success" is displayed.
Screen display
SAVE : Play
5. Press the [ BACK/ HOME] button, return to test mode menu
screen.
53
] buttons to select the "Contrast
V
Current contrast value
NAME :
Success
4-3. LCD LED Light
The lighting state of the LCD and the each indicator can be checked.
Procedure:
1. Enter the test mode.
(Refer to "1. SETTING THE TEST MODE" on page 51)
2. Press the [
DPC]/[ A-B
v
Light".
Test mode menu screen
Version
Contrast Setting
LCD LED Light
Sleep
OFF DeepSleep
Power Down
Key Count
HotPlug Count
Log
3. Press the [
] button to display the LCD and each indicator
N
lighting check screen.
(It turns into the white screen with all segments and lamps
turned off)
Screen display
All segments
All segments
off
on
Display
Display
pattern 2
pattern 1
Button input settings under this mode of operation:
[
]/[
] : Screen display pattern change
.
>
[
STOP]
: [
REC] indicator on/off change
x
z
[
REC]
: Peak level indicators and [
z
cator on/off change
4. Press the [ BACK/ HOME] button, return to test mode menu
screen.
4-4. Sleep
Note: Not used for the servicing.
4-5. OFF DeepSleep
Note: Not used for the servicing.
4-6. Power Down
Note: Not used for the servicing.
4-7. Key Count
Note: Not used for the servicing.
If you accidentally executed this mode and entered it, return to the test
mode menu screen by removing the batteries, inserting them again
and turning the power on.
Even if you removed the batteries, test mode is not released.
4-8. HotPlug Count
Note: Not used for the servicing.
Sony CONFIDENTIAL
For Authorized Servicer
] buttons to select the "LCD LED
V
Peak level
indicators
[
REC
X
PAUSE]
indicator
[
REC]
z
indicator