Vapor Line Sizing And Cooling Capacity Loss; Physical Data - Bryant 165A Product Data

165a preferred series air conditioner with puron refrigerant 1-1/2 to 5 nominal tons (size 018 to 060)
Hide thumbs Also See for 165A:
Table of Contents

Advertisement

UNIT SIZE SERIES
Operating Weight lb (kg)
Shipping Weight lb (kg)
Compressor Type
REFRIGERANT
Control
Charge lb (kg)
COND FAN
Air Discharge
Air Qty (CFM)
Motor HP
Motor RPM
COND COIL
Face Area (Sq ft)
Fins per In.
Rows
Circuits
VALVE CONNECT. (In. ID)
Vapor
Liquid
REFRIGERANT TUBES (In. OD)
Rated Vapor*
Liquid
*Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
NOTE: See unit Installation Instruction for proper installation.

VAPOR LINE SIZING AND COOLING CAPACITY LOSS

LONG LINE APPLICATION: An application is considered
"Long line" when the total equivalent tubing length exceeds 80
ft. (24.38 m) or when there is more than 20 ft. (6.09 m) vertical
separation between indoor and outdoor units. These applications
require additional accessories and system modifications for
reliable system operation. The maximum allowable total
equivalent length is up to 250 ft. (76.2 m). The maximum
Maximum
Unit Nomi-
Vapor Line
Liquid Line
nal Size
Diameters
Diameters
(Btuh)
(In. OD)
(In. OD)
18000
1/2
1 Stage
3/8
5/8
Puron AC
5/8
24000
1 Stage
3/4
3/8
Puron AC
7/8
5/8
30000
1 Stage
3/8
3/4
Puron AC
7/8
5/8
36000
1 Stage
3/4
3/8
Puron AC
7/8
3/4
42000
1 Stage
3/8
7/8
Puron AC
1 1/8
3/4
48000
1 Stage
3/8
7/8
Puron AC
1 1/8
3/4
60000
1 Stage
7/8
3/8
Puron AC
1 1/8
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Applica-
tion Guidelines

PHYSICAL DATA

018--- B
024--- B
186 (89.4)
198 (89.8)
258 (117.0)
228 (103.4)
229 (103.9)
298 (135.2)
5.28 (2.39)
5.66 (2.57)
10.77 (4.89)
2140
2140
1/12
1/12
800
800
16.08
16.08
25
25
1
1
4
4
5/8
5/8
5/8
5/8
Standard
Application
26--- 50
51--- 80
81--- 100
(7.9--- 15.2)
(15.5--- 24.4)
(24.7--- 30.5)
1
2
3
0
0
1
0
1
1
0
0
0
0
0
0
1
2
3
0
0
1
0
0
0
1
2
4
0
1
1
0
0
0
0
1
2
0
0
1
0
0
0
0
1
2
0
0
1
0
0
0
1
2
4
0
1
2
0
0
0
030--- B
036--- B
259 (117.5)
320 (145.1)
299 (135.6)
355 (161.0)
Scroll
Puron® (R---410A)
TXV (Puron® Hard Shutoff)
10.03 (4.55)
10.80 (4.90)
Forward Swept, Propeller Type, Direct Drive
Vertical
2595
3265
1/10
1/6
800
800
18.30
18.30
20
20
2
2
6
6
3/4
3/4
3/8
3/4
3/4
3/8
vertical separation is 200 ft. (60.96 m) when outdoor unit is
above indoor unit, and up to 80 ft. (24.38 m) when the outdoor
unit is below the indoor unit. Refer to Accessory Usage Guideline
below for required accessories. See Longline Application
Guideline for required piping and system modifications. Also,
refer to the table below for the vapor tube diameters based on the
total length to minimize the cooling capacity loss.
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
Long Line Application Requires Accessories
101--- 125
126--- 150
151--- 175
(30.8--- 38.1)
(38.4--- 45.7)
(46.0--- 53.3)
4
6
1
1
2
3
0
1
0
0
3
4
1
1
0
1
5
6
2
2
0
1
2
3
1
1
0
0
3
4
1
2
0
0
5
6
2
3
1
1
3
042--- B
048--- B
060--- B
326 (147.9)
330 (149.7)
361 (163.7)
365 (165.6)
11.40 (5.17)
13.17 (5.97)
3265
3673
1/6
1/4
800
800
24.40
24.40
20
20
2
2
8
8
7/8
7/8
7/8
7/8
176--- 200
201--- 225
(53.6--- 61.0)
(61.3--- 68.6)
7
8
9
2
2
3
3
4
4
1
1
1
0
0
0
5
6
7
2
2
2
1
1
1
8
9
10
3
3
4
1
1
2
4
4
5
2
2
2
0
0
0
5
5
6
2
2
3
0
0
1
7
9
10
4
4
5
1
1
1
3673
1/4
800
24.40
20
2
8
7/8
1 ---1/8
226--- 250
(68.9--- 76.2)
10
3
5
1
0
8
3
1
12
4
2
6
3
0
7
3
1
11
5
1