Bryant EVOLUTION 16 186B Product Data

Bryant EVOLUTION 16 186B Product Data

Evolution 16 air conditioner with puron refrigerant 1-1/2 to 5 tons

Advertisement

186B
R
EVOLUTION
16 AIR CONDITIONER
WITH PURONr REFRIGERANT
1- -1/2 TO 5 TONS
the environmentally sound refrigerant
Bryant's Air Conditioners with Puronr refrigerant provide a
collection of features unmatched by any other family of
equipment. The 186B has been designed utilizing Bryant's Puron
refrigerant. The environmentally sound refrigerant allows you to
make a responsible decision in the protection of the earth's ozone
layer.
This product has been designed and manufactured to meet
Energy Starr criteria for energy efficiency when matched with
appropriate coil components. Refer to the combination ratings in
the Product Data for system combinations that meet Energy Starr
guidelines.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S
S
S
Sound
S
S
Comfort
S
Reliability
®
S
S
S
S
S
S
S
Durability
DuraGuard Plust protection package:
S
S
S
Applications
S
S
14 - - 16 SEER / 11.0- - 13.5 EER
Microtube Technologyt refrigeration system
Indoor air quality accessories available
Sound level as low as 68 dBA
Compressor sound blanket standard
System supports Evolution Control or standard
thermostat controls
Puronr refrigerant - - environmentally sound, won't
deplete the ozone layer and low lifetime servce cost.
Scroll compressor
Internal pressure relief valve
Internal thermal overload
Filter drier
High and low pressure switches
Balanced refrigeration system for maximum reliability
Solid, durable sheet metal construction
Louvered coil guard
Baked- -on, complete outer coverage, powder paint
Long- -line - - up to 250 feet (76.20 m) total equivalent
length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)
Low ambient (down to
accessory kit
- -20_F/- -28.9_C)) with

Advertisement

Table of Contents
loading

Summary of Contents for Bryant EVOLUTION 16 186B

  • Page 1: Product Data

    Internal thermal overload collection of features unmatched by any other family of Filter drier equipment. The 186B has been designed utilizing Bryant’s Puron High and low pressure switches refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone Balanced refrigeration system for maximum reliability layer.
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Tier SEER Major Se- Voltage Variations Cooling Capacity Open Open Open Minor Family ries Series 1=AC 6=16 B=Puron 0=Not Evolution SEER Standard Defined Original 208--- 230--- 1 Series Nominal Defined Defined Series the environmentally sound refrigerant Use of the AHRI Certified TM Mark indicates a manufacturer’s...
  • Page 3: Refrigerant Piping Length Limitations

    REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puronr Refrigerant The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units.
  • Page 4: Long Line Applications

    REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft (g/m) 0.60 (17.74) (Factory charge for lineset = 9 oz / 266.16 g) 5/16 0.40 (11.83) 0.27 (7.98) Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or diameter liquid lines, charge adjustments are required per the chart above.
  • Page 5: Accessory Usage Guideline

    ACCESSORIES KIT NUMBER KIT NAME 018--- A 024--- A 030--- A 036--- A 042--- A 048--- A 060--- A 061--- A KAACH1701AAA CRANKCASE HTR KAACH1601AAA CRANKCASE HTR STANDARD CRANKCASE HTR KAAFT0101AAA FREEZE THERMOSTAT KSAHS2701AAA HARD START (CAP/RELAY) LOW---AMBIENT PRESSURE KSALA0301410 SWITCH KAACS0201PTC PTC START ASSIST...
  • Page 6 1. Compressor Start Assist - - Capacitor and Relay 7. Outdoor Air Temperature Sensor Start capacitor and relay gives a ”hard” boost to compressor Designed for use with Bryant Thermostats listed in this motor at each start up. publication. This device enables the thermostat to display the outdoor temperature.
  • Page 7: Electrical Data

    ELECTRICAL DATA FUSE** OPER VOLTS* COMPR WIRE WIRE LENGTH LENGTH UNIT SIZE --- V/PH or CKT SIZE{ SIZE{ ft (m)} ft (m)} SERIES 60° C 75° C 60° C 75° C AMPS 018--- A 48.0 11.8 66 (20.12) 62 (18.90) 024--- A 58.3 13.5...
  • Page 10 Wall...
  • Page 11 — Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
  • Page 16: Condenser Only Ratings

    CONDENSER ONLY RATINGS* CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 186BNA018****A 14.00 13.50 13.00 12.40 11.80 11.00 10.20 9.30 65.20 74.80 84.40...
  • Page 17 CONDENSER ONLY RATINGS* CONTINUED CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 186BNA036****A 30.50 29.20 27.80 26.30 24.70 23.00 21.20 19.20 69.50 78.70...
  • Page 18 CONDENSER ONLY RATINGS* CONTINUED CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 186BNA060000BAAA 45.10 43.80 42.30 40.50 38.50 36.20 33.50 30.50 69.00 78.40...
  • Page 19 GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM AIR CONDITIONER 186B GENERAL 1- -1/2 TO 5 NOMINAL TONS — Condenser fan motors will be totally enclosed, 1- -phase System Description type with class B insulation and permanently lubricated Outdoor- -mounted, air- -cooled, split- -system air conditioner bearings.
  • Page 20 SYSTEM DESIGN SUMMARY 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01- -in. wc. 2. Minimum outdoor operating air temperature without low- -ambient operation accessory is 55_F (12.8_C). 3.