Bryant 116B Product Data

Bryant 116B Product Data

116b series legacy line 16 air conditioner with puron refrigerant 1-1/2 to 5 nominal tons (sizes 018--060)

Advertisement

116B
Legacyt Line 16 Air Conditioner
with Puronr Refrigerant
1- -1/2 to 5 Nominal Tons (Sizes 018- - 060)
the environmentally sound refrigerant
Bryant's Air Conditioners with Puronr refrigerant provide a
collection of features unmatched by any other family of
equipment. The 116B has been designed utilizing Bryant's Puron
refrigerant. The environmentally sound refrigerant allows you to
make a responsible decision in the protection of the earth's ozone
layer.
As an Energy Starr Partner, Bryant Heating and Cooling has
determined that this product meets the Energy Starr guidelines
for energy efficiency. Refer to the combination ratings in the
Product Data for system combinations that meet Energy Starr
guidelines.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S
S
S
Sound
S
S
Comfort
S
Reliability
S
S
S
S
S
S
Durability
DuraGuardt protection package:
S
S
S
Applications
S
S
14 - - 16.5 SEER/11.0- - 13.5 EER
Microtube Technologyt refrigeration system
Indoor air quality accessories available
Sound level as low as 76 dBA
Sound level as low as 74 dBA with accessory sound
blanket
System supports Thermidistatt or standard thermostat
controls
Puronr refrigerant - - environmentally sound, won't
deplete the ozone layer and low lifetime servce cost.
Scroll compressor
Internal pressure relief valve
Internal thermal overload
Filter drier
Balanced refrigeration system for maximum reliability
Solid, durable sheet metal construction
Dense wire coil guard standard
Baked- -on, complete outer coverage, powder paint
Long- -line - - up to 250 feet (76.20 m) total equivalent
length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)
Low ambient (down to
accessory kit
- -20_F/- -28.9_C)) with

Advertisement

Table of Contents
loading

Summary of Contents for Bryant 116B

  • Page 1: Product Data

    Bryant’s Air Conditioners with Puronr refrigerant provide a Durability collection of features unmatched by any other family of equipment. The 116B has been designed utilizing Bryant’s Puron DuraGuardt protection package: refrigerant. The environmentally sound refrigerant allows you to Solid, durable sheet metal construction make a responsible decision in the protection of the earth’s ozone...
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Prod- Major Grille Cooling Capacity Tier SEER Voltage Open Open Open Series Series Variations Family 0=Not 208--- 230--- 1 A = Dense 0=Not 0=Not 1=AC Legacy 6=16 SEER B=Puron Defined W = Standard Defined Defined 208/230--- 1 ISO 9001:2000 the environmentally sound refrigerant REGISTERED...
  • Page 3 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puronr Refrigerant The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units.
  • Page 4 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft 0.60 (Factory charge for lineset = 9 oz) 5/16 0.40 0.27 Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or diameter liquid lines, charge adjustments are required per the chart above.
  • Page 5 ACCESSORY THERMOSTATS THERMOSTAT / SUBBASE DESCRIPTION PKG. T6---PRH01---A Programmable Thermidistat T6---NRH01---A Non--- programmable Thermidistat T6---PAC01 Preferred Series Programmable AC Stat T6---NAC01 Preferred Series Non--- programmable AC Stat T2---PAC01 Legacy Series Programmable AC Stat T2---NAC01 Legacy Series Non--- programmable AC Stat T1---PAC01 Legacy RNC Series Programmable AC Stat T1---NAC01...
  • Page 6 Required in long line applications. 9. Outdoor Air Temperature Sensor Suggested in all commercial applications. Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.
  • Page 7 Accessory Description and Usage (Listed Alphabetically) (Continued) 10. Sound Hood 13. Time- -Delay Relay Wraparound sound reducing cover for the compressor. Reduces An SPST delay relay which briefly continues operation of indoor the sound level by about 2 dBA. blower motor to provide additional cooling after the compressor cycles off.
  • Page 8: Electrical Data

    ELECTRICAL DATA OPER VOLTS* COMPR MIN WIRE MIN WIRE MAX FUSE** LENGTH LENGTH SIZE{ SIZE{ or CKT BRK UNIT SIZE V/PH ft. (m)} ft. (m)} 60° C 75° C AMPS RLA FLA 60° C 75° C 018--- B 48.0 0.50 11.8 67 (20.4) 64 (19.5)
  • Page 11 Wall...
  • Page 12 COMBINATION RATINGS ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3632435 116BNA018****B †CNPV*1917A**+TDR 18,000 12.0 14.5 3632420 116BNA018****B CAP**1814A** 313*AV024045 18,000 13.0 15.5 3632395 116BNA018****B CAP**1814A** 315(A,J)AV036070 18,000 12.5 15.5 3632429 116BNA018****B CAP**1814A**+TDR 18,000 11.5 13.5 3632421 116BNA018****B CAP**2414A** 313*AV024045...
  • Page 13: Combination Ratings Continued

    COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3632446 116BNA018****B FX4CNF018 18,000 13.0 15.5 3632447 116BNA018****B FX4CNF024 18,000 13.0 16.0 3632448 116BNA018****B FX4DNF019 18,000 13.0 16.0 3632449 116BNA018****B FX4DNF025 18,000 13.0 16.0 3632450 116BNA018****B FY4ANF018 18,000 11.5...
  • Page 14 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3632511 116BNA024****A CNPH*2417A** 315(A,J)AV066155 22,800 12.5 15.5 3632647 116BNA024****A CNPH*2417A** 353(A,B)AV036040 23,200 13.0 16.0 3632663 116BNA024****A CNPH*2417A** 353(A,B)AV036060 23,200 13.0 16.0 3663515 116BNA024****A CNPH*2417A** 353AAV036040 23,200 13.0 16.0 3632525...
  • Page 15 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3632557 116BNA024****A CNPH*3617A** 355(A,C)AV060100 23,000 13.0 16.0 3632564 116BNA024****A CNPH*3617A** 355(A,C)AV060120 23,200 13.0 16.0 3632570 116BNA024****A CNPH*3617A** 355AAV042040 23,000 13.0 16.0 3635396 116BNA024****A CNPH*3617A** 355BAV042060 23,200 13.0 16.0 3635409...
  • Page 16 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3635402 116BNA024****A CNPV*3621A** 355BAV042060 23,200 13.0 16.0 3635410 116BNA024****A CNPV*3621A** 355BAV042080 23,000 13.0 16.0 3635418 116BNA024****A CNPV*3621A** 355BAV060080 22,800 13.0 16.0 3635426 116BNA024****A CNPV*3621A** 355BAV060100 23,000 13.0 16.0 3632613...
  • Page 17 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3632864 116BNA030****A †CNPV*3117A**+TDR 28,600 12.0 14.5 3632684 116BNA030****A CAP**3014A** 315(A,J)AV036070 27,600 13.0 15.2 3632849 116BNA030****A CAP**3014A**+TDR 28,000 12.0 14.0 3632929 116BNA030****A CAP**3017A** 353(A,B)AV036080 28,000 13.0 16.0 3632946 116BNA030****A CAP**3017A**...
  • Page 18 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3632804 116BNA030****A CAP**4224A** 355(A,C)AV060120 28,000 13.0 16.0 3632812 116BNA030****A CAP**4224A** 355AAV042040 28,000 13.0 16.0 3635456 116BNA030****A CAP**4224A** 355BAV042080 28,000 13.0 16.0 3635468 116BNA030****A CAP**4224A** 355BAV060080 28,000 13.0 16.0 3635480...
  • Page 19 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3632815 116BNA030****A CNPH*3617A** 355AAV042040 27,800 12.5 15.5 3635443 116BNA030****A CNPH*3617A** 355BAV042060 28,000 13.0 15.5 3635459 116BNA030****A CNPH*3617A** 355BAV042080 27,600 12.5 15.5 3635471 116BNA030****A CNPH*3617A** 355BAV060080 27,800 12.5 15.5 3635483...
  • Page 20 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3663528 116BNA030****A CNPV*3621A** 353AAV036040 28,200 13.0 16.0 3632762 116BNA030****A CNPV*3621A** 355(A,C)AV042060 28,000 13.0 15.5 3632775 116BNA030****A CNPV*3621A** 355(A,C)AV042080 27,600 12.5 15.5 3632787 116BNA030****A CNPV*3621A** 355(A,C)AV060080 27,800 12.5 15.5 3632799...
  • Page 21 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3632743 116BNA030****A CSPH*3612A** 315(A,J)AV066155 28,400 13.0 16.0 3632909 116BNA030****A CSPH*3612A** 353(A,B)AV036040 28,800 13.0 16.0 3632926 116BNA030****A CSPH*3612A** 353(A,B)AV036060 28,800 13.0 16.0 3663536 116BNA030****A CSPH*3612A** 353AAV036040 28,800 13.0 16.0 3632766...
  • Page 22 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3632963 116BNA036****A CAP**3617A** 315(A,J)AV036070 32,800 12.0 15.0 3632974 116BNA036****A CAP**3617A** 315(A,J)AV048090 33,000 12.5 15.5 3663649 116BNA036****A CAP**3617A** 353(A,B)AV036060 33,200 12.5 15.0 3663632 116BNA036****A CAP**3617A** 353AAV036040 33,200 12.5 15.5 3633036...
  • Page 23 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3635502 116BNA036****A CAP**4817A** 355BAV042060 34,000 13.0 16.0 3663588 116BNA036****A CAP**4817A**+TDR 34,000 11.5 14.0 3663670 116BNA036****A CAP**4821A** 353(A,B)AV036080 33,800 13.0 16.0 3663695 116BNA036****A CAP**4821A** 353(A,B)AV048080 34,000 13.0 15.5 3663539 116BNA036****A...
  • Page 24 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3663573 116BNA036****A CNPH*4221A** 313*AV060110 33,600 13.0 16.0 3632966 116BNA036****A CNPH*4221A** 315(A,J)AV036070 33,000 12.0 15.0 3632980 116BNA036****A CNPH*4221A** 315(A,J)AV048090 33,200 12.5 15.5 3632997 116BNA036****A CNPH*4221A** 315(A,J)AV060110 33,200 12.5 15.5 3633009...
  • Page 25 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3635524 116BNA036****A CNPV*3621A** 355BAV042080 32,800 12.0 15.0 3635539 116BNA036****A CNPV*3621A** 355BAV060080 32,800 12.0 15.0 3635554 116BNA036****A CNPV*3621A** 355BAV060100 33,000 12.0 15.0 3663598 116BNA036****A CNPV*3621A**+TDR 33,000 11.5 13.5 3663665 116BNA036****A...
  • Page 26 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3633112 116BNA036****A CNPV*4824A** 355AAV042040 33,600 12.5 15.5 3635527 116BNA036****A CNPV*4824A** 355BAV042080 33,800 12.5 15.5 3635542 116BNA036****A CNPV*4824A** 355BAV060080 33,600 13.0 16.0 3635557 116BNA036****A CNPV*4824A** 355BAV060100 33,800 13.0 16.0 3635566...
  • Page 27 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3632990 116BNA036****A CSPH*4812A** 315(A,J)AV048090 33,800 13.0 16.0 3633005 116BNA036****A CSPH*4812A** 315(A,J)AV060110 34,000 13.0 16.0 3633014 116BNA036****A CSPH*4812A** 315(A,J)AV066135 34,000 13.0 16.0 3633023 116BNA036****A CSPH*4812A** 315(A,J)AV066155 34,000 13.0 16.0 3663664...
  • Page 28 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3663944 116BNA042****A CAP**4224A** 355(A,C)AV060080 39,500 12.5 15.0 3663977 116BNA042****A CAP**4224A** 355(A,C)AV060100 39,500 12.5 15.0 3664007 116BNA042****A CAP**4224A** 355(A,C)AV060120 39,500 13.0 15.2 3664032 116BNA042****A CAP**4224A** 355AAV042040 39,500 12.5 15.0 3635585...
  • Page 29 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3635588 116BNA042****A CAP**6021A** 355BAV042080 41,000 12.5 15.0 3635606 116BNA042****A CAP**6021A** 355BAV060080 41,000 13.0 15.5 3635624 116BNA042****A CAP**6021A** 355BAV060100 40,500 13.0 15.5 3664182 116BNA042****A CAP**6021A**+TDR 41,500 12.0 14.5 3664089 116BNA042****A...
  • Page 30 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3664039 116BNA042****A CNPH*4321A** 355AAV042040 40,500 12.5 15.0 3635575 116BNA042****A CNPH*4321A** 355BAV042060 41,000 13.0 15.5 3635591 116BNA042****A CNPH*4321A** 355BAV042080 41,000 12.5 15.0 3635609 116BNA042****A CNPH*4321A** 355BAV060080 41,000 13.0 15.5 3635627...
  • Page 31 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3664328 116BNA042****A CNPV*4221A** 353(A,B)AV048080 40,000 12.5 15.0 3664071 116BNA042****A CNPV*4221A** 313*AV048070 39,500 12.0 14.5 3664098 116BNA042****A CNPV*4221A** 313*AV048090 40,000 12.5 15.0 3664132 116BNA042****A CNPV*4221A** 313*AV060110 40,000 13.0 15.5 3663780...
  • Page 32 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3664139 116BNA042****A CNPV*6024A** 313*AV060110 41,500 13.0 16.0 3664163 116BNA042****A CNPV*6024A** 313*AV060135 41,500 13.0 16.0 3663816 116BNA042****A CNPV*6024A** 315(A,J)AV060110 41,000 13.0 16.0 3663840 116BNA042****A CNPV*6024A** 315(A,J)AV066135 41,000 13.0 16.0 3663864...
  • Page 33 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3663882 116BNA042****A CSPH*4812A** 359BAV060100 41,000 13.0 15.5 3664211 116BNA042****A CSPH*4812A**+TDR 41,000 12.0 14.0 3664322 116BNA042****A CSPH*6012A** 353(A,B)AV036080 41,500 13.0 16.0 3664336 116BNA042****A CSPH*6012A** 353(A,B)AV048080 41,500 13.0 16.0 3664078 116BNA042****A...
  • Page 34 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3664418 116BNA048****A CAP**4824A** 355(A,C)AV060080 44,000 12.5 14.5 3664431 116BNA048****A CAP**4824A** 355(A,C)AV060100 44,500 12.5 14.5 3664443 116BNA048****A CAP**4824A** 355(A,C)AV060120 44,500 12.5 14.5 3635653 116BNA048****A CAP**4824A** 355BAV060080 44,000 12.5 14.5 3635666...
  • Page 35 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3664472 116BNA048****A CNPH*6124A** 313*AV060110 45,500 13.0 15.5 3664483 116BNA048****A CNPH*6124A** 313*AV060135 45,500 13.0 15.0 3664373 116BNA048****A CNPH*6124A** 315(A,J)AV048090 45,500 13.0 15.0 3664383 116BNA048****A CNPH*6124A** 315(A,J)AV060110 45,500 13.0 15.0 3664394...
  • Page 36 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3664487 116BNA048****A CSPH*4812A** 313*AV060135 45,000 13.0 15.0 3664375 116BNA048****A CSPH*4812A** 315(A,J)AV048090 45,000 12.5 14.5 3664388 116BNA048****A CSPH*4812A** 315(A,J)AV060110 45,000 12.5 14.5 3664398 116BNA048****A CSPH*4812A** 315(A,J)AV066135 45,000 13.0 15.0 3664408...
  • Page 37 — Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
  • Page 53 CONDENSER ONLY RATINGS CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 116BNA018****B 15.70 14.90 14.10 13.20 12.30 11.30 10.20 9.20 66.60 76.20 85.80...
  • Page 54 CONDENSER ONLY RATINGS CONTINUED CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 116BNA042****A 37.90 36.20 34.30 32.30 30.10 27.90 25.50 23.00 69.80 79.20...
  • Page 55 GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM AIR CONDITIONER 116B GENERAL 1- -1/2 TO 5 NOMINAL TONS Fans System Description — Condenser fan will be direct- -drive propeller type, Outdoor- -mounted, air- -cooled, split- -system air conditioner unit discharging air upward.
  • Page 56 8. Do not apply capillary tube indoor coils to these units. 9. Factory- -supplied filter drier must be installed. Catalog No: PDS116B---01 Copyright 2010 Bryant Heating & Cooling Systems. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 01/10 Replaces: New Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Table of Contents