Bryant LEGACY 123A Manual

Bryant LEGACY 123A Manual

Legacy line 13 air conditioner with puron refrigerant 1-1/2 to 5 nominal tons (size 018 to 060)

Advertisement

123A
LEGACYt LINE 13 AIR CONDITIONER
WITH PURONR REFRIGERANT
1- -1/2 TO 5 NOMINAL TONS (SIZE 018 TO 060)
the environmentally sound refrigerant
Bryant's Air Conditioners with Puron r refrigerant provide a
collection of features unmatched by any other family of equipment.
Air Conditioner model 123A has been designed utilizing Bryant's
Puron refrigerant. The environmentally sound refrigerant allows
you to make a responsible decision in the protection of the earth's
ozone layer.
As an Energy Star r Partner, Bryant Heating & Cooling has
determined that this product meets the Energy Starr guidelines for
energy efficiency. Refer to the combination ratings in the Product
Data for system combinations that meet Energy Starr guidelines.
NOTE: Ratings contained in this document are subject to
change at any time.
Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

INDUSTRY LEADING FEATURES / BENEFITS
EFFICIENCY
S
S
S
SOUND
S
COMFORT
S
RELIABILITY
S
S
S
S
S
S
S
S
S
DURABILITY
TM
DuraGuardt protection package:
S
S
S
S
APPLICATIONS
S
S
13 - - 15 SEER/11 - - 12 EER
Microtube Technologyt refrigeration system
Indoor air quality accessories available
Sound level as low as 74 dBA
System supports Thermidistatt Control or standard
thermostat
Puronr refrigerant - - environmentally sound, won't
deplete the ozone layer and low lifetime servce cost.
Front- -seating service valves
Scroll compressor
Internal pressure- -relief valve
Internal thermal overload
Low- -pressure switch
High- -pressure switch
Filter drier
Balanced refrigeration system for maximum reliability
Solid, durable sheet metal construction
Steel louver coil guard
Baked- -on, complete outer coverage, powder paint
Color matched cabinet screws
Long- -line - - up to 250 feet (76.20 m) total equivalent
length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)
Low ambient (down to - -20_F/- -28.9_C) with accessory
kit

Advertisement

Table of Contents
loading

Summary of Contents for Bryant LEGACY 123A

  • Page 1: Product Data

    80 ft. (24.38 m) evaporator above As an Energy Star r Partner, Bryant Heating & Cooling has condenser (See Longline Guide for more information.) determined that this product meets the Energy Starr guidelines for Low ambient (down to - -20_F/- -28.9_C) with accessory...
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Tier SEER Major Voltage Variations Cooling Capacity Open Open Open Minor Family Series Series 1=AC 3=13 A=Puron A = Standard 0=Not N=208/230--- 1 Legacy SEER Defined Original P = 208/230--- 3 (Nominal) Defined Defined Series E = 460/3 ISO 9001:2000 Use of the AHRI Certified the environmentally sound refrigerant...
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE --- SERIES 018--- C 024--- C 030--- C 036--- C 042--- C 048--- C 060--- C Operating Weight lb (kg) (59.0) (59.0) (64.4) (73.0) (93.0) (103.4) (113.9) Shipping Weight lb (kg) (68.5) (68.5 (74.4) (83.5) (105.7) (116.1) (129.3) Compressor Type...
  • Page 4 ACCESSORIES UNIT SIZE--- SERIES (Voltage) 018--- C 024--- C 030--- C 30--- C 036--- C 36--- C 36--- C 042--- C 42--- C 42--- C 048--- C 48--- C 48--- C 060--- C 60--- C 60--- C ORDER NUMBER DESCRIPTION KAACH1201AAA CRANKCASE HTR KAACH1301AAA CRANKCASE HTR KAACH1401AAA CRANKCASE HTR...
  • Page 5 ACCESSORY USAGE GUIDELINE REQUIRED FOR LONG REQUIRED FOR REQUIRED FOR LOW---AMBI- LINE SEA COAST ENT COOLING APPLICATIONS ACCESSORY APPLICATIONS* APPLICATIONS (Below 55°F/12.8_C) (Over 80 ft./24.38 m) (Within 2 miles/3.22 km) Ball Bearing Fan Motor Yes{ Compressor Start Assist Capacitor and Relay Crankcase Heater Evaporator Freeze Thermostat Hard Shut---Off TXV...
  • Page 6 ACCESSORY DESCRIPTION AND USAGE (LISTED ALPHABETICALLY) (CONT) 9. Outdoor Air Temperature Sensor 11. Thermostatic Expansion Valve (TXV) Designed for use with Bryant Thermostats listed in this A modulating flow- -C (N)ontrol valve which meters refrigerant publication. This device enables the thermostat to display the liquid flow rate into the evaporator in response to the superheat of outdoor temperature.
  • Page 7: Electrical Data

    ELECTRICAL DATA OPER UNIT SIZE FUSE** COMPR WIRE WIRE LENGTH LENGTH VOLTS* --- SERIES or CKT V/PH SIZE{ SIZE{ ft (m)} ft (m)} (VOLTAGE) MIN. 60° C 75° C 60° C 75° C AMPS 018--- C (N) 48.0 11.7 67 (20.4) 64 (19.5) 024--- C (N) 58.3...
  • Page 10 Wall...
  • Page 11 COMBINATION RATINGS AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3045607 123ANA018---C *CAP**1814A**+TDR 17500 11.00 13.00 3045642 123ANA018---C CAP**1814A** 313*AV024045 17500 12.20 14.50 3045608 123ANA018---C CAP**1814A** 315(A,J)AV036070 17200 11.70 14.50 3045643 123ANA018---C CAP**2414A** 313*AV024045 17800 12.20 14.50 3045610 123ANA018---C...
  • Page 12: Combination Ratings Continued

    COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3101649 123ANA024---C CNPV*2417A** 353AAV036060 22800 12.00 14.00 3101650 123ANA024---C CNPV*2417A** 353AAV036080 22800 12.00 14.00 3045661 123ANA024---C CNPV*2417A** 355(A,C)AV042060 22400 11.50 14.00 3045660 123ANA024---C CNPV*2417A**+TDR 22600 11.00 13.00 3045708...
  • Page 13 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3045742 123ANA030---C CNPH*3617A** 315(A,J)AV036070 27400 11.50 14.00 3101686 123ANA030---C CNPH*3617A** 353AAV036040 28000 12.00 14.00 3101687 123ANA030---C CNPH*3617A** 353AAV036060 28000 12.00 14.00 3101688 123ANA030---C CNPH*3617A** 353AAV036080 28000 12.00 14.00...
  • Page 14 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3046695 123APA030---C CNPH*3017A** 315(A,J)AV036070 27400 11.50 14.00 3124211 123APA030---C CNPH*3017A** 353AAV036040 28000 12.00 14.00 3124212 123APA030---C CNPH*3017A** 353AAV036060 28000 12.00 14.00 3124213 123APA030---C CNPH*3017A** 353AAV036080 28000 12.00 14.00...
  • Page 15 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3045835 123ANA036---C CAP**4221A** 313*AV060110 34400 12.20 14.50 3045789 123ANA036---C CAP**4221A** 315(A,J)AV060110 34000 11.50 14.00 3101703 123ANA036---C CAP**4221A** 353AAV060100 34000 12.20 14.50 3045788 123ANA036---C CAP**4221A** 355(A,C)AV042080 33800 11.50 14.00...
  • Page 16 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3045823 123ANA036---C FE4ANB006+UI 35400 12.00 15.00 3045820 123ANA036---C FE4ANF002+UI 33600 11.50 14.00 3045824 123ANA036---C FF1ENP036 33800 11.00 13.00 3045826 123ANA036---C FV4BN(B,F)003 34000 11.70 14.50 3045827 123ANA036---C FV4BN(B,F)005 35000...
  • Page 17 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3046805 123APA036---C CSPH*3612A** 313*AV024045 34000 11.70 13.50 3046806 123APA036---C CSPH*3612A** 313*AV048070 34000 12.00 14.00 3046807 123APA036---C CSPH*3612A** 313*AV048090 34000 12.00 14.50 3046808 123APA036---C CSPH*3612A** 313*AV060110 34000 12.00 14.50...
  • Page 18 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3046839 123AEA036---C CNPH*4221A**+TDR 34000 11.00 13.00 3046870 123AEA036---C CNPV*3617A** 313*AV048070 33600 11.70 13.50 3046829 123AEA036---C CNPV*3617A** 315(A,J)AV048090 33400 11.50 14.00 3124337 123AEA036---C CNPV*3617A** 353AAV036040 34000 12.00 14.00 3124338...
  • Page 19 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3045910 123ANA042---C CAP**4824A** 313*AV060135 41000 12.00 14.00 3045871 123ANA042---C CAP**4824A** 315(A,J)AV066135 41000 11.70 14.50 3101741 123ANA042---C CAP**4824A** 353AAV060120 41000 12.20 14.50 3045870 123ANA042---C CAP**4824A** 355(A,C)AV042040 41000 11.20 13.50...
  • Page 20 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3045895 123ANA042---C FY4ANF048 42000 11.00 13.20 3046891 123APA042---C *CAP**4221A**+TDR 41000 11.00 13.00 3046938 123APA042---C CAP**4221A** 313*AV048090 40500 11.70 14.00 3046939 123APA042---C CAP**4221A** 313*AV060110 40500 12.00 14.00 3046893 123APA042---C...
  • Page 21 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3124294 123APA042---C CSPH*4212A** 353AAV060100 40500 12.00 14.00 3124295 123APA042---C CSPH*4212A** 353AAV060120 40500 12.00 14.00 3046923 123APA042---C CSPH*4212A** 355(A,C)AV042040 40000 11.20 13.50 3046922 123APA042---C CSPH*4212A**+TDR 40500 11.00 13.20 3046962...
  • Page 22 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3047020 123AEA042---C CNPV*4221A** 313*AV048090 40500 11.70 14.00 3047021 123AEA042---C CNPV*4221A** 313*AV060110 40500 11.70 14.00 3046983 123AEA042---C CNPV*4221A** 315(A,J)AV060110 40000 11.50 14.00 3124379 123AEA042---C CNPV*4221A** 353AAV060100 40500 12.00 14.00...
  • Page 23 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3045967 123ANA048---C CNPH*4821A** 355(A,C)AV060080 45000 11.00 13.20 3045968 123ANA048---C CNPH*4821A** 355(A,C)AV060100 45000 11.20 13.50 3045966 123ANA048---C CNPH*4821A**+TDR 46000 11.00 13.00 3046004 123ANA048---C CNPH*6024A** 313*AV048070 45500 11.00 13.00 3046005...
  • Page 24 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3047103 123APA048---C CNPH*4821A** 313*AV048090 45500 11.50 13.50 3047104 123APA048---C CNPH*4821A** 313*AV060110 45500 11.70 13.50 3047105 123APA048---C CNPH*4821A** 313*AV060135 45500 11.50 13.20 3047071 123APA048---C CNPH*4821A** 315(A,J)AV048090 45000 11.20 13.50...
  • Page 25 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3047127 123AEA048---C CAP**6021A** 355(A,C)AV060080 46000 11.20 13.50 3047126 123AEA048---C CAP**6021A**+TDR 47000 11.00 13.20 3047174 123AEA048---C CAP**6024A** 313*AV060135 46000 11.70 14.00 3047131 123AEA048---C CAP**6024A** 315(A,J)AV066135 46500 11.50 14.00 3124410...
  • Page 26 COMBINATION RATINGS CONTINUED AHRI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3046039 123ANA060---C CNPH*6024A** 313*AV060110 56000 11.00 13.00 3046040 123ANA060---C CNPH*6024A** 313*AV060135 56000 11.00 13.00 3046024 123ANA060---C CNPH*6024A** 315(A,J)AV066135 56000 11.20 13.50 3046025 123ANA060---C CNPH*6024A** 315(A,J)AV066155 56500 11.20 13.50...
  • Page 27 TDR — Time---Delay Relay. In most cases, only one method should be used to achieve TDR function. Using more than one method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay, KAATD0101TDR, or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
  • Page 35 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 123A*A018--- C 15.90 15.00 14.10 13.10 12.20 11.20 10.20 9.10 67.80 77.30 86.80...
  • Page 36 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 123A*A042--- C 38.00 36.00 33.90 31.90 29.70 27.60 25.30 22.90 73.20 82.30 91.40...
  • Page 37 GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM AIR CONDITIONER 123A GENERAL 1- -1/2 TO 5 NOMINAL TONS Fans System Description — Condenser fan will be direct- -drive propeller type, Outdoor- -mounted, air- -cooled, split- -system air conditioner unit discharging air upward.
  • Page 38 Catalog No. PDS123A ---04 E 2009 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 02/09 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Table of Contents