Electrical Data; Weighted Sound Power (Dba); Weighted Sound Power With Sound Blanket (Dba); Charging Subcooling (Tvx - Type Expansion Device) - Bryant 113A Product Data

Legacy-rnc line 13 air conditioner with puron refrigerant 1--1/2 to 5 nominal tons (sizes 018--060)
Hide thumbs Also See for 113A:
Table of Contents

Advertisement

ELECTRICAL DATA

UNIT
OPER VOLTS*
SIZE ---
V/PH
VOLTAGE,
SERIES
MAX
018--- D
024--- D
030--- E
036--- E
208/230/1
253
042--- C
048--- E
060--- F
* Permissible limits of the voltage range at which the unit will operate satisfactorily
{ If wire is applied at ambient greater than 30_C (86_F), consult table 310 ---16 of the NEC (ANSI/NFPA 70). The ampacity of non ---metallic---sheathed cable
(NM), trade name ROMEX, shall be that of 60_C (140_F) conditions, per the NEC (ANSI/NFPA 70) Article 336 ---26. If other than uncoated (no ---plated), 60 or
75_C (140 or 167_F) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the
NEC (ANSI/NFPA 70).
Length shown is as measured one way along wire path between unit and service panel for voltage drop not to exceed 2%.
}
** Time ---Delay fuse.
FLA --- Full Load Amps
LRA --- Locked Rotor Amps
MCA --- Minimum Circuit Amps
RLA --- Rated Load Amps
NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
A- - WEIGHTED SOUND POWER (dBA)
STANDARD
UNIT SIZE ---
RATING
SERIES
(dBA)
018--- D
72
024--- D
76
030--- E
74
036--- E
75
042--- C
78
048--- E
80
060--- F
78
NOTE: Tested in accordance with ARI Standard 270 ---95 (not listed in ARI).
A- - WEIGHTED SOUND POWER WITH SOUND BLANKET (dBA)
STANDARD
UNIT SIZE ---
RATING
SERIES
(dBA)
018--- D
71
024--- D
74
030--- E
73
036--- E
74
042--- C
77
048--- E
79
060--- F
78
NOTE: Tested in accordance with ARI Standard 270 ---95 (not listed in ARI).
CHARGING SUBCOOLING (TXV- -TYPE EXPANSION DEVICE)
UNIT SIZE --- SERIES
COMPR
FAN
MIN
LRA
RLA
FLA
48.0
9.0
58.3
13.5
0.75
64.0
12.8
197
77.0
14.1
112.0
17.9
109.0
19.9
134.0
26.4
TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)
125
250
53.5
59.5
55.0
61.5
55.0
63.5
59.5
63.0
57.5
65.0
58.5
67.5
59.0
67.5
TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)
125
250
55.5
60.5
55.5
60.5
55.5
64.0
59.5
63.0
57.5
65.0
60.5
67.5
59.0
68.0
018--- D
024--- D
030--- E
036--- E
042--- C
048--- E
060--- F
MIN WIRE
MIN WIRE
SIZE{
MCA
60° C
0.5
11.8
14
17.6
14
1.4
16.8
14
1.4
20.5
12
1.1
23.5
12
1.4
26.2
10
1.2
34.2
8
500
1000
63.5
67.0
67.0
71.5
68.5
68.5
68.5
70.0
71.0
73.0
73.5
75.0
71.5
73.5
500
1000
64.0
66.0
68.5
70.0
68.0
67.0
68.0
69.5
70.5
72.0
73.5
74.5
70.5
72.5
REQUIRED SUBCOOLING _F (_C)
7
MAX
MAX
LENGTH
LENGTH
SIZE{
(FT)}
(FT)}
75° C
60° C
75° C
14
66 (20.1)
63 (21.0)
14
44 (13.4)
42 (12.8)
14
46 (14.0)
44 (13.4)
12
61 (18.6)
58 (17.7)
12
53 (16.2)
51 (15.5)
10
76 (23.2)
72 (22.2)
10
62 (18.9)
55 (16.8)
2000
4000
63.5
59.0
69.0
61.0
65.5
61.0
65.5
61.5
70.5
67.5
70.5
67.5
69.0
66.0
2000
4000
63.0
58.5
67.0
61.0
64.0
60.0
65.0
60.5
70.0
67.0
71.0
68.0
68.0
67.0
8 (4.4)
13 (7.2)
16 (8.9)
14 (7.8)
10 (5.6)
15 (8.3)
11 (6.1)
MAX
FUSE**
or CKT
BRK
AMPS
15
25
25
30
40
40
50
8000
52.5
55.0
54.0
53.5
62.5
64.5
63.5
8000
52.0
53.6
52.5
50.5
62.0
63.5
63.0