Legacy-rnc line 13 air conditioner with puron refrigerant 1--1/2 to 5 nominal tons (sizes 018--060)

Advertisement

113A
Legacy- -RNC Line 13 Air Conditioner
with Puronr Refrigerant
1- -1/2 to 5 Nominal Tons (Sizes 018- -060)
the environmentally sound refrigerant
Bryant's Air Conditioners with Puron r refrigerant provide a
collection of features unmatched by any other family of equipment.
The 113A has been designed utilizing Bryant's Puron refrigerant.
The environmentally sound refrigerant allows you to make a
responsible decision in the protection of the earth's ozone layer.
As an Energy Star r Partner, Bryant Heating and Cooling has
determined that this product meets the Energy Starr guidelines for
energy efficiency. Refer to the combination ratings in the Product
Data for system combinations that meet Energy Starr guidelines.
NOTE: Ratings contained in this document are subject to
change at any time.
Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

Efficiency
S 13 - - 14.5 SEER/10.55 - - 12 EER
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S Sound level as low as 76 dBA
S Sound level as low as 74 dBA with accessory sound blanket
Comfort
S System supports Thermidistatt or standard thermostat controls
Reliability
S Puronr refrigerant - - environmentally sound, won't deplete the
ozone layer and low lifetime service cost.
S Scroll compressor
S Internal pressure relief valve
S Internal thermal overload
S Filter drier
S Balanced refrigeration system for maximum reliability
Durability
DuraGuardt protection package:
S Solid, durable sheet metal construction
S Dense wire coil guard
S Baked- -on, complete outer coverage, powder paint
Applications
S Long- -line - - up to 250 feet (76.20 m) total equivalent length, up
to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft.
(24.38 m) evaporator above condenser (See Longline Guide for
more information.)
S Low ambient (down to - -20_F/- -28.9_C) with accessory kit
Warranty
S 5 year limited compressor warranty
S 5 year limited parts warranty
INDUSTRY LEADING
FEATURES / BENEFITS

Advertisement

Table of Contents
loading

Summary of Contents for Bryant 113A

  • Page 1: Product Data

    The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer. As an Energy Star r Partner, Bryant Heating and Cooling has determined that this product meets the Energy Starr guidelines for energy efficiency.
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Major Tier SEER Family Series 1=AC Legacy 3=13 SEER A=Puron the environmentally sound refrigerant Feature Puron Refrigerant Maximum SEER Scroll Compressor Dense Wire Coil Guard Field Installed Filter Drier Front Seating Service Valves Internal Pressure Relief Valve Internal Thermal Overload Long Line capability Low Ambient capability with Kit...
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE --- VOLTAGE, SERIES Operating Weight lb (kg) Shipping Weight lb (kg) Compressor Type REFRIGERANT Control Charge lb (kg) COND FAN Air Discharge Air Qty (CFM) Motor HP Motor RPM COND COIL Face Area (Sq ft) Fins per In. Rows Circuits VALVE CONNECT.
  • Page 4: Accessories

    ACCESSORY THERMOSTATS THERMOSTAT / SUBBASE PKG. T6---PRH ---01 Programmable Thermidistat T6---NRH ---01 Non--- programmable Thermidistat T1---PAC ---01 Legacy RNC Series Programmable AC Stat T1---NAC ---01 Legacy RNC Series Non--- programmable AC Stat TSTATBBPRH01---B Thermidistat Control --- Programmable / Non--- Programmable Thermostat with Humidity control TSTATBBPAC01---B Thermostat --- Auto Changeover, 7--- Day Programmable, _F/_C, 1--- Stage Heat, 1--- Stage Cool TSTATBBNAC01---C...
  • Page 5: Accessory Usage

    55_F (12.8_C). Suggested for all commercial applications. 9. Outdoor Air Temperature Sensor Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.
  • Page 6 Relay is required. Usage Guideline: Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 13. Time- -Delay Relay...
  • Page 7: Electrical Data

    ELECTRICAL DATA UNIT OPER VOLTS* SIZE --- V/PH VOLTAGE, SERIES 018--- D 48.0 024--- D 58.3 030--- E 64.0 036--- E 208/230/1 77.0 042--- C 112.0 048--- E 109.0 060--- F 134.0 * Permissible limits of the voltage range at which the unit will operate satisfactorily { If wire is applied at ambient greater than 30_C (86_F), consult table 310 ---16 of the NEC (ANSI/NFPA 70).
  • Page 12 Wall...
  • Page 13 COMBINATION RATINGS ARI Ref. No. Model Number 3163097 113ANA018---BD †CAP**1814A**+TDR 3163099 113ANA018---BD 3163098 113ANA018---BD 3163102 113ANA018---BD 3163101 113ANA018---BD 3163100 113ANA018---BD CAP**2414A**+TDR 3163105 113ANA018---BD 3163106 113ANA018---BD 3163107 113ANA018---BD 3163104 113ANA018---BD 3163103 113ANA018---BD CAP**2417A**+TDR 3163128 113ANA018---BD CNPF*2418A**+TDR 3163125 113ANA018---BD 3163123 113ANA018---BD 3163124 113ANA018---BD 3163126 113ANA018---BD...
  • Page 14: Combination Ratings Continued

    COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number 3163185 113ANA024---BD 3163186 113ANA024---BD 3163187 113ANA024---BD 3163188 113ANA024---BD 3163183 113ANA024---BD 3163182 113ANA024---BD CNPH*2417A**+TDR 3163210 113ANA024---BD 3163205 113ANA024---BD 3163206 113ANA024---BD 3163207 113ANA024---BD 3163208 113ANA024---BD 3163209 113ANA024---BD 3163211 113ANA024---BD 3163212 113ANA024---BD 3163213 113ANA024---BD 3163200 113ANA024---BD 3163201 113ANA024---BD...
  • Page 15 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number 3163250 113ANA024---BD 3163247 113ANA024---BD 3163248 113ANA024---BD 3163257 113ANA030---BE †CAP**3014A**+TDR 3163268 113ANA030---BE 3163272 113ANA030---BE 3163271 113ANA030---BE 3163273 113ANA030---BE 3163274 113ANA030---BE 3163275 113ANA030---BE 3163276 113ANA030---BE 3163270 113ANA030---BE 3163269 113ANA030---BE CAP**3017A**+TDR 3163278 113ANA030---BE 3163277 113ANA030---BE CAP**3614A**+TDR 3163282 113ANA030---BE...
  • Page 16 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number 3163307 113ANA030---BE 3163308 113ANA030---BE 3163309 113ANA030---BE 3163310 113ANA030---BE 3163304 113ANA030---BE 3163303 113ANA030---BE CNPV*3617A**+TDR 3163316 113ANA030---BE 3163315 113ANA030---BE 3163312 113ANA030---BE 3163313 113ANA030---BE 3163314 113ANA030---BE 3163311 113ANA030---BE CNPV*3621A**+TDR 3163366 113ANA030---BE 3163367 113ANA030---BE 3163361 113ANA030---BE 3163362 113ANA030---BE 3163363...
  • Page 17 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number 3019805 113ANA036---E 3099586 113ANA036---E 3019806 113ANA036---E 3019807 113ANA036---E 3019808 113ANA036---E 3019811 113ANA036---E CAP**4221A**+TDR 3019812 113ANA036---E 3019813 113ANA036---E 3038785 113ANA036---E 3019814 113ANA036---E 3019815 113ANA036---E 3019816 113ANA036---E CAP**4224A**+TDR 3019817 113ANA036---E CNPF*3618A**+TDR 3019829 113ANA036---E 3019830 113ANA036---E 3019831 113ANA036---E...
  • Page 18 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number 3019863 113ANA036---E 3019864 113ANA036---E 3019859 113ANA036---E 3099600 113ANA036---E 3019860 113ANA036---E 3019861 113ANA036---E 3019862 113ANA036---E 3019865 113ANA036---E CNPV*4221A**+TDR 3019877 113ANA036---E 3019878 113ANA036---E 3019879 113ANA036---E 3019866 113ANA036---E 3019867 113ANA036---E 3019868 113ANA036---E 3019869 113ANA036---E 3019870 113ANA036---E 3099611 113ANA036---E...
  • Page 19 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number 3099515 113ANA042---C 3099516 113ANA042---C 3099517 113ANA042---C 3038825 113ANA042---C 3038824 113ANA042---C CAP**4817A**+TDR 3038795 113ANA042---C 3038796 113ANA042---C 3038829 113ANA042---C 3099518 113ANA042---C 3038828 113ANA042---C 3038827 113ANA042---C CAP**4821A**+TDR 3038797 113ANA042---C 3038832 113ANA042---C 3038831 113ANA042---C 3038830 113ANA042---C CAP**4824A**+TDR 3038848 113ANA042---C...
  • Page 20 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number 3038849 113ANA042---C CSPH*4212A**+TDR 3038815 113ANA042---C 3038816 113ANA042---C 3038817 113ANA042---C 3038818 113ANA042---C 3038854 113ANA042---C 3099548 113ANA042---C 3099549 113ANA042---C 3099550 113ANA042---C 3099551 113ANA042---C 3099552 113ANA042---C 3099553 113ANA042---C 3038853 113ANA042---C 3038852 113ANA042---C CSPH*4812A**+TDR 3038859 113ANA042---C 3038860 113ANA042---C 3038861...
  • Page 21 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number 3023128 113ANA048---E CNPH*6024A**+TDR 3022978 113ANA048---E 3022979 113ANA048---E 3022977 113ANA048---E 3099566 113ANA048---E 3022975 113ANA048---E 3022976 113ANA048---E 3023129 113ANA048---E CNPV*4821A**+TDR 3022983 113ANA048---E 3022981 113ANA048---E 3022982 113ANA048---E 3099567 113ANA048---E 3022980 113ANA048---E 3023130 113ANA048---E CNPV*4824A**+TDR 3022987 113ANA048---E 3022985 113ANA048---E...
  • Page 22 TDR — Time---Delay Relay In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
  • Page 35 80.50 (10.0) 1.73 48.80 82.60 (12.78) 1.77 See notes on page 36 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 75 (23.89) 85 (29.44) 95 (35.0) 113A*A018--- D 15.20 14.20 13.30 12.30 80.40 89.90 99.50 109.10 0.95 1.09 1.24 1.40 16.70...
  • Page 36 SDT --- Saturated Temperature Leaving Compressor (° F/° C) SST --- Saturated Temperature Entering Compressor (° F/° C) TCG --- Gross Cooling Capacity (1000 Btuh) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 75 (23.89) 85 (29.44) 95 (35.0) 113A*A042--- C 36.00 33.90 31.90 29.70 82.30 91.40 100.60...
  • Page 37 GUIDE SPECIFICATIONS GENERAL System Description Outdoor- -mounted, air- -cooled, split- -system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air- -cooled coil, propeller- -type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings.
  • Page 38 Catalog No. PDS113A ---04 E2008 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 09/08 Replaces: PDS113A--- 03 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Table of Contents