Bryant 113A Product Data

Bryant 113A Product Data

Legacy series rnc line 13 air conditioner with puron refrigerant 1-1/2 to 5 nominal tons (sizes 018-060)
Hide thumbs Also See for 113A:

Advertisement

113A
LegacytRNC Line 13 Air Conditioner
with Puronr Refrigerant
1- -1/2 to 5 Nominal Tons (Sizes 018- - 060)
the environmentally sound refrigerant
Bryant's Air Conditioners with Puronr refrigerant provide a
collection of features unmatched by any other family of
equipment. The 113A has been designed utilizing Bryant's Puron
refrigerant. The environmentally sound refrigerant allows you to
make a responsible decision in the protection of the earth's ozone
layer.
As an Energy Starr Partner, Bryant Heating and Cooling has
determined that this product meets the Energy Starr guidelines
for energy efficiency. Refer to the combination ratings in the
Product Data for system combinations that meet Energy Starr
guidelines.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S
S
S
Sound
S
S
Comfort
S
Reliability
S
S
S
S
S
S
Durability
DuraGuardt protection package:
S
S
S
Applications
S
S
13 - - 14 SEER/10.55 - - 12 EER
Microtube Technologyt refrigeration system
Indoor air quality accessories available
Sound level as low as 75 dBA
Sound level as low as 74 dBA with accessory sound
blanket
System supports Thermidistatt or standard thermostat
controls
Puronr refrigerant - - environmentally sound, won't
deplete the ozone layer and low lifetime servce cost.
Scroll compressor
Internal pressure relief valve
Internal thermal overload
Filter drier
Balanced refrigeration system for maximum reliability
Solid, durable sheet metal construction
Dense wire coil guard available
Baked- -on, complete outer coverage, powder paint
Long- -line - - up to 250 feet (76.20 m) total equivalent
length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)
Low ambient (down to
accessory kit
- -20_F/- -28.9_C)) with

Advertisement

Table of Contents
loading

Summary of Contents for Bryant 113A

  • Page 1: Product Data

    Bryant’s Air Conditioners with Puronr refrigerant provide a Durability collection of features unmatched by any other family of equipment. The 113A has been designed utilizing Bryant’s Puron DuraGuardt protection package: refrigerant. The environmentally sound refrigerant allows you to Solid, durable sheet metal construction make a responsible decision in the protection of the earth’s ozone...
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Major Grille Cooling Capacity Tier SEER Voltage Open Open Open Series Family Series Variations 0=Not N= 208--- 230--- 1 A = Dense 0=Not 0=Not Defined 1=AC 3=13 SEER A=Puron Legacy RNC or 208/230--- 1 W = Standard Defined Defined ISO 9001:2000...
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE ---VOLTAGE, SERIES 018---D 024---D 030---E 036---E 042---C 048---E 060---G Operating Weight lb (kg) (48.5) (49.9) (50.3) (64.0) (85.7) (84.4) (86.2) Shipping Weight lb (kg) (59.0) (60.8) (61.7) (77.1) (98.4) (101.6) (102.5) Compressor Type Scroll REFRIGERANT Puron® (R--- 410A) Control TXV (Puron®...
  • Page 4: Refrigerant Piping Length Limitations

    REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puronr Refrigerant The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units.
  • Page 5: Long Line Applications

    REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft 0.60 (Factory charge for lineset = 9 oz) 5/16 0.40 0.27 Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or diameter liquid lines, charge adjustments are required per the chart above.
  • Page 6: Accessory Thermostats

    ACCESSORY THERMOSTATS THERMOSTAT / SUBBASE DESCRIPTION PKG. T6---PRH01---A Programmable Thermidistat T6---NRH01---A Non--- programmable Thermidistat T6---PAC01 Preferred Series Programmable AC Stat T6---NAC01 Preferred Series Non--- programmable AC Stat T2---PAC01 Legacy Series Programmable AC Stat T2---NAC01 Legacy Series Non--- programmable AC Stat T1---PAC01 Legacy RNC Series Programmable AC Stat T1---NAC01...
  • Page 7: Accessory Usage Guideline

    Required in long line applications. 9. Outdoor Air Temperature Sensor Suggested in all commercial applications. Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.
  • Page 8 Accessory Description and Usage (Listed Alphabetically) (Continued) 10. Sound Hood 13. Time- -Delay Relay Wraparound sound reducing cover for the compressor. Reduces An SPST delay relay which briefly continues operation of indoor the sound level by about 2 dBA. blower motor to provide additional cooling after the compressor cycles off.
  • Page 9: Electrical Data

    ELECTRICAL DATA OPER MIN WIRE MIN WIRE UNIT FUSE** COMPR LENGTH LENGTH SIZE --- VOLTS* SIZE{ SIZE{ or CKT V/PH ft. (m)} ft. (m)} VOLTAGE, SERIES 60° C 75° C 60° C 75° C AMPS 48.0 11.8 66 (20.1) 63 (21.0) 018--- D 58.3 13.5...
  • Page 12 Wall...
  • Page 13: Combination Ratings

    COMBINATION RATINGS ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3250604 113AN(A,W)018---D †CAP**1814A**+TDR 17600 10.90 13.00 3250606 113AN(A,W)018---D CAP**1814A** 313*AV024045 17800 12.00 14.50 3250605 113AN(A,W)018---D CAP**1814A** 315(A,J)AV036070 17500 12.00 14.50 3250609 113AN(A,W)018---D CAP**2414A** 313*AV024045 18000 12.20 14.50 3250608 113AN(A,W)018---D CAP**2414A**...
  • Page 14: Combination Ratings Continued

    COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3251111 113AN(A,W)024---D CNPH*2417A** 355(A,C)AV042060 23200 12.00 14.00 3251112 113AN(A,W)024---D CNPH*2417A** 355(A,C)AV042080 22800 12.00 14.00 3251113 113AN(A,W)024---D CNPH*2417A** 355(A,C)AV060080 22600 12.00 14.00 3251114 113AN(A,W)024---D CNPH*2417A** 355(A,C)AV060100 22800 12.00 14.00 3251115...
  • Page 15 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3251182 113AN(A,W)024---D FV4BNF002 22600 12.00 14.00 3251176 113AN(A,W)024---D FX4CNF024 23200 11.70 14.00 3251177 113AN(A,W)024---D FX4CNF030 23400 12.00 14.50 3251174 113AN(A,W)024---D FY4ANF024 23000 11.00 13.00 3251175 113AN(A,W)024---D FY4ANF030 23200 11.00...
  • Page 16 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3251237 113AN(A,W)030---E CNPV*3617A** 313*AV048070 27400 11.50 14.00 3251236 113AN(A,W)030---E CNPV*3617A** 315(A,J)AV048090 27400 11.70 14.00 3251238 113AN(A,W)030---E CNPV*3617A** 353AAV036040 27200 12.00 14.50 3251239 113AN(A,W)030---E CNPV*3617A** 353AAV036060 27200 12.00 14.50 3251240...
  • Page 17 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3250958 113AN(A,W)036---E CAP**3621A** 355(A,C)AV060100 33600 11.70 14.00 3250955 113AN(A,W)036---E CAP**3621A**+TDR 33800 10.90 13.00 3251050 113AN(A,W)036---E CAP**4221A** 313*AV048090 34000 12.00 14.00 3251051 113AN(A,W)036---E CAP**4221A** 313*AV060110 34200 12.00 14.00 3250964 113AN(A,W)036---E...
  • Page 18 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3250919 113AN(A,W)036---E CNPV*4217A** 353AAV036040 33800 11.70 14.00 3250920 113AN(A,W)036---E CNPV*4217A** 353AAV036060 33800 11.70 14.00 3250921 113AN(A,W)036---E CNPV*4217A** 353AAV036080 33800 11.70 14.00 3250922 113AN(A,W)036---E CNPV*4217A** 353AAV048080 33800 11.70 14.00 3250916...
  • Page 19 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3250728 113AN(A,W)042---C CAP**4224A** 315(A,J)AV066135 40500 11.50 14.00 3250683 113AN(A,W)042---C CAP**4224A** 353AAV060120 40500 12.00 14.00 3250727 113AN(A,W)042---C CAP**4224A** 355(A,C)AV042040 40000 11.20 13.50 3250726 113AN(A,W)042---C CAP**4224A**+TDR 41000 11.00 13.00 3250657 113AN(A,W)042---C...
  • Page 20 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3250712 113AN(A,W)042---C CSPH*4212A** 353AAV036040 41000 11.70 14.00 3250713 113AN(A,W)042---C CSPH*4212A** 353AAV036060 41000 11.70 14.00 3250714 113AN(A,W)042---C CSPH*4212A** 353AAV036080 41000 11.70 14.00 3250715 113AN(A,W)042---C CSPH*4212A** 353AAV048080 41000 11.70 14.00 3250716...
  • Page 21 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER 3250825 113AN(A,W)048---E CNPH*6024A** 315(A,J)AV066155 46000 12.20 14.50 3250871 113AN(A,W)048---E CNPH*6024A** 353AAV048080 45000 11.50 13.50 3250872 113AN(A,W)048---E CNPH*6024A** 353AAV060100 45000 12.00 14.00 3250873 113AN(A,W)048---E CNPH*6024A** 353AAV060120 45000 12.00 14.00 3250819...
  • Page 22 1. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
  • Page 32: Condenser Only Ratings

    CONDENSER ONLY RATINGS* CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 113AN(A,W)018--- D 16.10 15.20 14.20 13.30 12.30 11.30 10.20 9.10 70.80 80.40...
  • Page 33 CONDENSER ONLY RATINGS* CONTINUED CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 113AN(A,W)042--- C 38.00 36.00 33.90 31.90 29.70 27.60 25.30 22.90 73.20...
  • Page 34 — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. Catalog No. PDS113A ---07 E2009 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 03/09 Replaces: PDS113A--- 06...

This manual is also suitable for:

Legacy 113a

Table of Contents