• Drive and steer functions can only be performed after
the DOS override switch (on the platform console) has
been engaged. Drive and steer functions can be oper-
ated at normal speed;
• All the structure movements (Mast and Jib Lift, Swing)
remain unaffected by the DOS.
Main Mast Limit Switch
The main mast limit switch determines whether the plat-
form is in Transport position (mast fully lowered) or in Ele-
vated position. When the main mast limit switch is tripped:
• Max. driving speed is reduced from approx. 5.5 km/h
to approx. 0.75 km/h.
Secondary Mast Limit Switch (Toucan 10E only)
The secondary mast limit switch is used to detect when
the mast is close to the max. elevation. When the second-
ary mast limit switch is tripped:
Max. driving speed is reduced from approx. 0.75 km/h to
approx 0.4 km/h.
Platform Gate Switches (If equipped)
Two gate switches are used to detect when a gate is
opened. When one of the switches is tripped:
• All the movements are cut out from the platform con-
sole.
Battery Charger Interlock
When the battery charger is connected to the mains, the
information is sent to the control system. If the battery
charger is connected to the mains:
• All the movements are cut out from the platform con-
sole if the MACHINE SETUP, CHARGER INTERLOC is
set to CUTOUT ALL;
• Drive and steer functions are cut out if the MACHINE
SETUP, CHARGER INTERLOC is set to DRIVE ONLY.
Battery Discharge Indication
The battery status is continuously monitored by the MAS-
TER MODULE. Indication is given to the operator through
both the MDI and the platform console panel. Functions
limitations are applied depending on three status:
charged, discharged (which corresponds to 70% dis-
charge) and deeply discharged (which corresponds to
80% discharged).
If the battery is charged, no function limitation is applied.
If the battery is discharged:
• The max. driving speed, in transport position, is
reduced by 50%. Out of transport position, driving
speed is not affected;
• Mast Lift Up, Jib Lift Up and Swing maximum speeds
are reduced (same parameter as for tilted condition is
used);
• Mast Lift Down and Jib Lift Down can be operated at
normal speed.
If the battery is deeply discharged:
• Mast Lift Up and Jib Lift Up are cut out;
• The max. driving speed is limited at 0.4 km/h, whatever
the platform position is;
31210090
SECTION 3 - THEORY OF OPERATION
• Max. swing speed is reduced;
• Mast Lift Down and Jib Lift Down can be operated at
normal speed.

Personality Settings and Calibration

Functions performances may be altered by changing the
applicable personality settings or calibrating different ele-
ments of the control system.
Refer to Section 9 of this manual for the applicable proce-
dures.
– JLG Lift –
3-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Toucan 20eToucan 10eToucan 26e

Table of Contents