Control Components - Service; Battery Maintenance And Safety Practices - JLG TOUCAN 8E Service And Maintenance Manual

Hide thumbs Also See for TOUCAN 8E:
Table of Contents

Advertisement

1.
Platform Control Station
2.
Ground Control Station
3.
Battery Pack
4.
Battery Charger
5.
Main Contactor Power Relay
6.
Power Fuse
7.
Power Module - Master
8.
Power Module - Slave
9.
Mast Elevation Limit Switch(es)
10.
Chain Slack Sensors
11.
Overload Sensor
12.
Drive Orientation Switch
13.
Steering Sensor
14.
Tilt Sensor
15.
Ground Alarm
16.
Warning Beacon
17.
Descent/Motion Alarm (Optional)
18.
Battery Centralized Filling Switch

8.2 CONTROL COMPONENTS - SERVICE

NOTICE
BEFORE REMOVING ANY COMPONENT FROM THE ELECTRICAL
SYSTEM, DISCONNECT THE BATTERIES USING THE QUICK-DIS-
CONNECT LOCATED IN THE BATTERY PACK COMPARTMENT.

Battery Maintenance and Safety Practices

ENSURE THAT BATTERY ACID DOES NOT COME INTO CONTACT
WITH SKIN OR CLOTHING. WEAR PROTECTIVE CLOTHING AND
EYEWEAR WHEN WORKING WITH BATTERIES. NEUTRALIZE ANY
BATTERY ACID SPILLS WITH BAKING SODA AND WATER.
R I N G S , W A T C H E S O R A N Y O T H E R J E W E L R Y M U ST B E
REMOVED DURING MAINTENANCE OR ANY SERVICING OPERA-
TION ON THE BATTERY.
B A T T ER Y A C I D R E L EA SE S A N E XP L O SI V E G A S W H I L E
CHARGING, ALLOW NO OPEN FLAMES, SPARKS OR LIGHTED
TOBACCO PRODUCTS IN THE AREA WHILE CHARGING BATTER-
IES. CHARGE BATTERIES ONLY IN A WELL VENTILATED AREA.
ADD ONLY DISTILLED WATER TO BATTERIES. ADD WATER TO
BATTERIES AFTER CHARGING TO AVOID ELECTROLYTE OVER-
FLOW.
31210090
SECTION 8 - CONTROL COMPONENTS
DO NOT REPLACE ITEMS CRITICAL TO STABILITY, SUCH AS
BATTERIES, WITH ITEMS OF DIFFERENT WEIGHT OR SPECIFI-
CATION. DO NOT MODIFY UNIT IN ANY WAY TO AFFECT STABIL-
ITY.
Electrolyte Level:
Check the electrolyte level of the batteries often and add
only distilled water when required:
1.
Open access door to the battery compartment.
2.
Check proper electrolyte level after charge using the
floats (1) in the center of each cell filling cap.
3.
Fill the can (2) with distilled water.
4.
Depress and hold the push button (3) to activate the
filling pump. Release the button when the flow indi-
cator (4) slows down.
5.
Check for proper level in each cell (float on each
cell's cap). Actuate the filling pump again if some
cells show improper level.
– JLG Lift –
Figure 8-3. Battery filling
8-3