Can bus network
Table of Contents

Advertisement

Termination with MFD
The MFD unit is terminated with a terminator as shown in Fig.23, because the unit does not
have the internal terminator.
Backbone cable
to rest of bus
Internal Terminator
Furuno CAN bus devices, DRS, FI-50, GP-330B, SC-30, and WS-200 have an internal
terminator, so these devices can be connected to the backbone cable as shown in Fig.24.
By connecting the device to the backbone cable, the cable length between the T-connector
and the device can be extended more than 6 m.
Power supply
FI-50
Fig.24 Using internal terminator at both ends of backbone cable
To activate the internal terminator;
(a) DRS
The resistor assembly, 120 OHM-1007#24-L50, C/N: 000-167-746 is connected between
#5 and #6 of J603 in the radome antenna and #4 and #5 of TB102 in the open type
antenna.
Fig.25 Terminator in DRS2D/4D
In-line Terminator
Type: FRU-0505-FF-IS
C/N: 000-172-037-10
Fig.23 Termination with MFD
Device
#5 & #6
J603
Furuno CAN bus Network Design Guide
CAN bus cable or
or
NMEA2000 cable
Device
Device
#4 & #5
Fig.26 Terminator in DRS4A/6A/12A/25A
8
Female Terminator
GP-330B
TB102