1.10.3 Drop Cable Length
The total drop cable length must not exceed 60 m and no single drop cable should exceed 6
m.
1.10.4 Device Limitation
No more than 20 (LEN) CAN bus devices can be connected to the Furuno CAN bus network
powered from the DRS and through the MFD unit.
The total LEN of the devices connected to the heavy backbone cable should not exceed 160
and 20 for the light backbone cable.
Table 7 Total LEN vs. Heavy backbone cable length (Power source: 15 Vdc *)
Total
Max.
LEN
(m)
< 20
150
21
150
22
150
23
150
24
150
25
150
26
150
27
140
28
140
29
130
30
130
31
130
32
120
33
120
34
110
35
110
36
110
37
100
38
100
39
100
40
100
41
90
42
90
43
90
44
90
45
80
*: When 12 Vdc power source is connected to the network, divide the cable length in halves.
Total
Max.
Total
LEN
(m)
LEN
46
80
72
47
80
73
48
80
74
49
80
75
50
80
76
51
70
77
52
70
78
53
70
79
54
70
80
55
70
81
56
70
82
57
70
83
58
65
84
59
65
85
60
65
86
61
65
87
62
65
88
63
60
89
64
60
90
65
60
91
66
60
92
67
60
93
68
55
94
69
55
95
70
55
96
71
55
97
Furuno CAN bus Network Design Guide
Max.
Total
Max.
(m)
LEN
(m)
55
98
40
55
99
40
50
100
40
50
101
40
50
102
35
50
103
35
50
104
35
50
105
35
50
106
35
50
107
35
45
108
35
45
109
35
45
110
35
45
111
35
45
112
35
45
113
35
45
114
35
45
115
35
45
116
35
40
117
30
40
118
30
40
119
30
40
120
30
40
121
30
40
122
30
40
123
30
15
Total
Max.
LEN
(m)
124
30
125
30
126
30
127
30
128
30
129
30
130
30
131
30
132
30
133
30
134
30
135
30
136
30
137
25
138
25
139
25
140
25
142
25
144
25
146
25
148
25
150
25
152
25
154
25
156
25
160
25