Appendix C: NFS2-3030 and NCA-2 (UL 9th), AM2020/AFP1010, NFS-3030, or
C.1 Capabilities
When installed with NFS2-3030, NFS-3030, NCA-2, NCA, or AM2020/AFP1010, the LDM Series modules can annunciate the status of
addressable devices, software zones, XP Series Transponder points and several system control functions:
C.2 Devices
Intelligent Detectors
– MMX Monitor Modules and CMX Control Modules
– BGX Addressable Manual Pull Stations, security devices & all other addressable devices.
Software Zones, logic zones, and digital audio zones
All software zones can be annunciated provided that each zone is mapped to an annunciator point.
System Controls
– Acknowledge/Step (referred to as the ACK/STEP key)
– Signal Silence
– System Reset
– Lamp Test (test LEDs, printer & CRT terminal output on FACP/network annunciator only)
XP Series Transponder System
– Power and Audio Supply Supervision Point
– XPP-1 Form-C Alarm and Trouble Relay Points
– XPC Control, XPM Monitor and XPR Relay Module Circuit Points
C.3 Software Versions
All releases of NFS2-3030, NFS-3030, NCA, and ADT-NCA-2 are compatible with LDM series modules.
The AM2020/AFP1010 must be operating with software of the following part numbers (or greater):
AM2020/AFP1010 Board
Central Processing Unit (CPU-2020)
Display Interface Assembly (DIA-1)
Loop Interface Board (LIB-200)
CAUTION:
!
EACH SOFTWARE ROM INSTALLED IN THE AM2020/AFP1010 MUST BE PART OF THE SAME SOFTWARE
COMBINATION. FOR A LIST OF VALID SOFTWARE COMBINATION NUMBERS, CONTACT THE NOTIFIER
TECHNICAL SERVICES DEPARTMENT.
C.4 NFS2-3030, NCA-2, and NFS-3030
EIA-485 Connections
NCA-2 as shown in the accompanying illustration. The NFS-3030/NFS2-3030/NCA-2 must be at the
end of the EIA-485 circuit. EIA-485 connections are power-limited and supervised; see
Sections 4.3–4.6 for further details and notes about EIA-485 requirements.
Power Connections
NCA-2, or CPU-3030, as shown in the accompanying illustrations. Maximum current for both cir-
cuits on TB6 is 1 amp.
The power run to the annunciator does not require a Power Supervision Relay. Loss of power is
inherently supervised through a Communications loss. This 24 VDC output is supervised, filtered,
and non-resettable. TB6 on AMPS-24/E is power-limited only if the +5V output on the terminal
block is not used; refer to the AMPS-24 Manual for complete details & restrictions if choosing this option.
44
NCA (UL 8th)
One EIA-485 circuit may be connected to the CPU-3030/CPU2-3030 or
Connect the power run for the LDMs to TB6 on the AMPS-24/E, CPU2-3030,
TB6 on AMPS-24/E
ROM Part Number
73123
73132
73117 (for each LIB-200)
TB6 on CPU2-3030
TB6 on CPU-3030
and NCA-2
LDM Series Instruction Manual — P/N 15885:H3 8/12/2019
TB7 on NFS-3030/
NFS2-3030/NCA-2
+ -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Notifier ldm-32Notifier ldm-e32

Table of Contents