Gas Manifold Pressure
For natural gas, standard orifices are set for 4" W.C. (Water Column). A natural gas pres-
sure regulator is provided. For propane (LP) gas, standard orifices are set for 10" W.C. A
propane gas regulator with hose attachment for LP cylinder is provided. For plumbed-in LP
installation, use the convertible regulator and set it for LP gas.
Gas Supply Pressure
Maximum line pressure (before the regulator) for Natural gas and plumbed-in Progane is
14" W.C., ½ psig (3.5 kPa).
Maximum line pressure for Natural Gas is 7" W.C. Minimum line presure for propane is 11"
W.C.
Gas Pressure Regulator
The unit must be used with the gas pressure regulator. The regulator will control and main-
tain a uniform gas pressure in the manifold. The burner orifices have been sized for the
gas pressure delivered by the regulator.
Cylinder Specification
Any LP gas supply cylinder used with this grill must be approximately 12 inches in diameter
and 18 inches high. The maximum fuel capacity is 20 lbs. of propane or 5 gallons. Full
cylinder weight should be approximately 38 lbs. (43.7 lbs. nominal water capacity.) Always
use the cylinder dust cap on the cylinder valve outlet during transport and when the cylinder
is not connected to the grill.
Transporting the LP Gas Supply Cylinder
Only one cylinder should be transported at a time. Transport cylinder in an upright and
secure manner with control valve turned off and the dust cap in place.