Lincoln Electric INVERTEC V145-S Service Manual page 24

Hide thumbs Also See for INVERTEC V145-S:
Table of Contents

Advertisement

TEST PROCEDURE
1.
Remove main input power to the Invertec V145-S
2.
Remove secondary plastic cover, using a star screw driver
3.
Perform the Discharge Procedure
4.
Viasually check for burned area on the Input Board. Solder side
5.
Check with multimeter for continuity between "AC1" to " Point –A-" and "AC2" to "Point –B-"
6.
Check the input rectifier bridge "D1"
7.
Check Start resistance "R2" for 20 Ohms
AC1
Input rectifier
Bridge
Point
AC2
–B-
D1
1
1
R2 Start Resistor =
20 ohms
Point
–A-
2
24