Replacing The Stripper Finger Assembly - Xerox Versant 2100 Press Quick Start Manual

Hide thumbs Also See for Versant 2100 Press:
Table of Contents

Advertisement

12. Facing the right side of the drawer, push the module slightly away from you and lift
the Fuser Belt straight up and out of the press, letting the weight of the module hang
in your hands.
Note
Do not twist or rotate the module as you place it in the Holding Rack.
13. Place it on the Fuser Holding Rack provided. Align the edge of the roller to the scribe
mark on the holding rack frame.
14. If damaged or end-of-life, place it inside the original box and return to Xerox for
recycling.
15. With the Fuser Belt removed, you can now remove and replace the Fuser Stripper
Finger Bracket, the Fuser Pressure Roll Assembly and the Pressure Roll Cleaning Pad
Assembly. Refer to those procedures.
16. If a different width fuser is going to be installed, remove the new fuser from its
packaging. Store the unused fuser in its original box.
17. To install the fuser, refer to that procedure

Replacing the Stripper Finger Assembly

Caution
Make sure the press is powered off. Do not perform this replacement procedure with
the power on or electrical power supplied to the press. Allow the fuser to cool down for
50 minutes before performing any maintenance.
1. Perform the steps for
2. Once the Fuser Belt Assembly is out of the press, you can access and remove the
Fuser Stripper Finger baffle:
a) Using the T10 Torx driver, remove the two screws and the Fuser Entrance Baffle.
Set aside the screws for reinstallation.
b) Note the position of the Fuser Belt Edge Sensor so as not to damage it when
removing the Pressure Roll.
c) Press the front and back Spring Levers at the same time and lift out the Stripper
Finger Assembly.
3. To replace the Stripper Finger Assembly, align the two slots in the assembly with the
two posts and click into place.
4. Position the Entrance Baffle by aligning the two perforations and the two screw holes.
5. Reinstall the two screws to secure the baffle.
6. Ask the administrator to reset the HFSI count for this newly-replaced CRU component
at the press Control Panel.
Xerox
®
Versant 2100 Press
Quick Start Guide
Installing the Fuser
Removing the Fuser
Module.
Maintenance
Module.
5-25