7.2 Maximum Insulation Diameters and Wire Sizes

Conductor Size
26 gauge solid
0.4mm solid
24 gauge
0.5mm solid
Certain wire sizes other than those recommended above can be inserted in the contact IDC but
must be qualified individually. The specification of the cable using the stranded wire must have the
wire insulation type, wire insulation thickness, number of strands, size of strands and twist of
strands controlled.
Wire Size Range (mm²)
Min
1.00
Copyright FCI
Form E-3334
Rev F
TYPE
APPLICATION SPECIFICATION

7.2.1 Signal Contact

Insulation Diameter
mm
0.74
0.74
1.00
1.00

7.2.2 Power Contact

Insulation Diameter (mm)
Max
Min
2.50
2.00
Form E-3334
Rev F
PAGE
9 of 30
AUTHORIZED BY
Stalin Alosius
CLASSIFICATION
inch
0.0291
0.0291
0.0394
0.0394
Max
3.00
PDS: Rev :D