NUMBER
GS-20-0454
TITLE
OCTIS PLUG KIT ASSEMBLY – HYBRID, SIGNAL & POWER
10.2

Cable Preparation for Signal Contact

Step 1
Strip the outer jacket. (Fig 17)
Do not cut any wire of the braid
Step 2
Unweave the braid
Step 3
Fold back the braid
The braid should be equally distributed
No Bundles
Step 4
Cut the braid to 9mm (Fig 18)