OCTIS PLUG KIT ASSEMBLY – HYBRID, SIGNAL & POWER

8 ACCEPTABLE WIRE TERMINATION

Caution: The wire strain relief of each contact must be closed by the wire insertion punch even if no wire is
inserted into the contact. If the strain relieves are not closed, a short can occur between contacts on both
shielded and unshielded connectors or between the contact and metal shields on shielded connectors.
The automatic wire terminators will set all the unused contacts unless the machine cycle is interrupted.
When using hand tools, the operator must index the connector subassembly to all unused positions and
activate the hand tool.

8.1 Termination Requirements, Visual

Requirements for an acceptable termination as well as non-destructive visual inspection methods
to ensure satisfactory terminations without removing wires.

8.1.1 Wire location

The copper conductor shall extend at least 0.75mm beyond the IDC dimples. This
requirement shall be considered to meet if the wire insulation extends at least 1.00mm
beyond the IDC dimples. At a maximum the insulation may extend to surface "D" (See fig
4).