Table 8: Regulator States for Different Modes of Operation
Operating mode
Vref
Power off
Off
Power on
On
Reset
On
Sleep
Off
Note: CCONT includes five additional 2.8V regulators providing power to the RF section. These reg-
ulators can be controlled either by the direct control signals from MAD or by the RF regulator control
register in CCONT which MAD can update. Below are the listed the MAD control lines and the regu-
lators they control:
- TxPwr controls VTX regulator (VR7)
- RxPwr controls VRX regulators (VR2 and VR5)
- SynthPwr controls VSYN_1 and VSYN_2 regulators (VR1_SW and VR4)
VCXOPwr controls VXO regulator (VR1)
CCONT generates also a 1.5 V reference voltage VREF to COBBA, SUMMA, and CRFU. The
VREF voltage is also used as a reference to some of the CCONT A/D converters.
In addition to the above-mentioned signals, MAD includes TXP control signal, which goes
to SUMMA power control block and to the power amplifier. The transmitter power con-
trol TXC is led from COBBA to SUMMA.

Audio Control

The audio control and processing is handled by the COBBA–GJP, which contains the
audio and RF codecs, and the MAD2, which contains the MCU, ASIC, and DSP blocks
handling and processing the audio signals.
Page 30
RF REG
VCOBBA
Off
Off
On/Off
On
Off
On
VR1 On
Off
Off
Nokia Mobile Phones Ltd.
PAMS Technical Documentation
VBB
VSIM
Off
Off
On
On
On
On
On
On
SIMIF
Pull down
On/off
Pull down
On/off
Issue 1 03/01

Advertisement

Table of Contents
loading

Table of Contents