1. The wire gauge for the terminal block should be in
the range from 12 to 24 AWG.
2. Please check the wire AWG Ampere specification
Note
before connecting PLANET Industrial Managed Switch.
PWR1 and PWR2 must provide the same DC voltage
for power load balance while operating with dual power
input.
Caution

3.1 Grounding the Device

Users MUST complete grounding wired with the device; otherwise, a
sudden lightning could cause fatal damage to the device.
8
DI0
DI1 DO0 DO1
GND
GND
1 2 3 4 5 6
Max. fault loading: 24V, 1A
1 2 3 4 5 6
DC Input:
48-56V
Earth Ground
, 6A max.

Hide quick links: