Grounding The Device - Planet IGS-4215-8T4X Quick Installation Manual

Industrial l2/l4 managed gigabit switch with 10g uplink
Hide thumbs Also See for IGS-4215-8T4X:
Table of Contents

Advertisement

1. The wire gauge for the terminal block should be in the range
between 12 and 24 AWG.
2. The power input range of IGS-4215-8T4X is 9V ~ 48V DC
and supports 24V AC.
PWR1 and PWR2 must provide exactly the same DC voltage
for power load balance while operating with dual power input.

3.1 Grounding the Device

Users MUST complete grounding wiring with the device; otherwise, a sudden
lightning could cause fatal damage to the device.
6
Earth Ground
Dual power input is required
for maximum PoE loading.
Refer to user's manual for
more details.
DI0
DI1 DO0 DO1
1 2 3 4 5 6
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
V1+
PWR1
Alarm
Figure 3-2: IGS-4215-8UP4X
GND
GND
DC Input:
V2+
48-54V
, 8A max.
PWR2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Igs-4215-8up4x

Table of Contents