Technical Characteristics - Rinnai Shimanto 110 User's And Installer's Manual

Wall-mounted domestic hot water heat pump with water tank
Table of Contents

Advertisement

6.1 TECHNICAL CHARACTERISTICS

Power supply
Water tank real capacity
Heating capacity
Rated power input
Nominal current
SCOP
(ERP) ***
DHW
Max power input
Max current
Heating time with cold tank (***)
Stand-by power input (***)
Max. outlet water temperature
(without E-heater operation)
Max water temperature **
Minimum temperature for starting
Working ambient temperature
Refrigerant max. discharge pressure
Refrigerant max. suction pressure
Refrigerant type
Refrigerant GWP
Refrigerant charge
Amount fluorinated greenhouse gases
Compressor
Fan motor
Nominal air flow
Available static pressure
Air flow at 60 Pa
Duct diameter
Max allowed pressure water side
Relief valve setpoint (to install externally)
Material of of the inner surface of the tank
Auxiliary electric heater
Electronic expansion valve
Magnesium anode
Material of the heat pump exchanger (condenser)
Chilled water input
Hot water outlet
Condensed water outlet
Drainage
Power cable length
IP protection class
Net dimensions LxHxW
Packing Dimensions
Net Weight
Weight with full tank
Gross Weight
Sound power ****
NOTE:
*
Heating capacity, power input based on the following conditions:
- ambient temperature 20°C, water temperature from 15°C to 55°C (obtained results by internal laboratory tests
based on the uniform reintegration of the tank temperature).
**
In relation to the auxiliary electric heater. During the anti-legionella cycle, the temperature is raised to 70°C by the
electric heater.
*** Obtained with the tank stored at an ambient temperature of 20°C, with air inlet of the duct at 7°C and all other
parameters in accordance with EN 16147.
**** According to EN 12102: ducted unit in/out 2m.
44
TECHNICAL DATA
V/Ph/Hz
L
W
W
A
W/W
W
A
h:min
W
°C
°C
°C
°C
bar
bar
g
tCO
eq
2
Type
Oil (type)
Oil (q.ty)
Tipo
W
m3/h
Pa
m3/h
mm
bar
Bar
S235JR with double-layer vitrification
kW
inch
inch
Flexible plastic tube Ø18 mm
inch
To be installed externally
m
mm
mm
Kg
Kg
Kg
dB (A)
SHIMANTO 110
220-240/1/50
110
850* (+1500**)
236* (+1500**)
1,14* (+6,5**)
3,01
400 (+1500**)
1,81 (+6,5**)
6:53
13,4
60
70**
10
-5 ~ +43
25
0,2
R134a
1430
650
0,93
Rotary
68HES-H
376 ml
AC
20
300
60
170
DN 125
8
6
1,5
yes
yes
Copper
G 1/2 " male
G 1/2 " male
1,5
IPX1
500x520X1406
550x550x1460
72,0
182
84,0
48,5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehp-wh110

Table of Contents