Advertisement

Quick Links

Infinity 16
Internal FE
24 Hour Hot Water
In all areas
0800 746624

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai Infinity 16F

  • Page 1 Infinity 16 Internal FE 24 Hour Hot Water In all areas 0800 746624...
  • Page 2 New Zealand has a service and spare parts network in all areas. ring the 0800 Rinnai Service Current AS/NZS 3500.4 Current AS/NZS 3000 NZS 5261 Gas Installations Code.
  • Page 3 FEATURES AND BENEFITS ..................3 IMPORTANT OPERATIONAL SAFETY POINTS ...........4 SAFETY POINTS .......................5 WARNING ABOUT HOT WATER ................7 OPERATION WITHOUT TEMPERATURE CONTROLLERS ........8 TEMPERATURE CONTROLLERS ................9 STANDARD TEMPERATURE CONTROLLER ............10 OPERATION WITH STANDARD TEMPERATURE CONTROLLERS ....11 Using the Infinity with 1 Standard Temperature Controller ........11 Using the Infinity with 2 to 3 Standard Temperature Controllers ......12...
  • Page 4 temperature shown on the Digital Monitor (or the pre-set limit when Temperature Controllers are not fitted) the burner will be shut off until the outgoing hot water temperature falls to that shown on the Digital Monitor (or the pre-set limit). a.
  • Page 5: Important Operational Safety Points

    Block or obstruct any ventilation openings deemed necessary for the operation of this gas appliance by your installer. If abnormal operation, odour or noise are observed, stop operation and contact Rinnai. Release latch Air filter care: Clean air filter at least once a month.
  • Page 6: Safety Points

    SAFETY POINTS Do not touch the flue outlet whilst in operation. Do not insert objects into the flue outlet. Do not cover the filters whilst in operation. "K"Series only...
  • Page 7 SAFETY POINTS...
  • Page 8: Warning About Hot Water

    WARNING ABOUT HOT WATER in New Zealand Rinnai New Zealand...
  • Page 10 Infinity 16FE...
  • Page 11: Temperature Controllers

    16WF Use to transfer priority between temperature controllers. The controller with priority has command of hot water delivery temperature.
  • Page 13 to 3 indicator...
  • Page 14 Other controllers are unable to select priority.
  • Page 15 Reset the appliance by turning the Combustion time out (activated after 60 water heater off at the power point, minutes of continuous use to ensure that leave the unit off for 10 seconds and the room does not run out of oxygen) then turn the power back on.
  • Page 16: Filter Care

    FILTER CARE Your Infinity 16FE is provided with an air filter, this is located on the front panel of the appliance. To keep the unit operating correctly, inspect the filter regularly, cleaning at least once a month. To remove light dust or lint a vacuum cleaner may be used. DO NOT operate the appliance without the air filter fitted.
  • Page 17: Warranty

    Trade Practices Act Given installation is in accordance with the manufacturers specification, this appliance is warranted by Rinnai for the cost of labour and components in the event of defects arising from faulty materials and/or workmanship with the ensuing warranty conditions.

This manual is also suitable for:

Infinity 16fe

Table of Contents