6-3-5. Hot Start (Pulse Mode Only)

1

6-3-5-1. Start Power

In this menu the user can adjust the percentage of weld power applied during the start period. The start wire feed speed and all other pulse paramet-
ers are calculated to obtain the high heat input desired for a quality aluminum start.

6-3-5-2. Start Time

In this menu the user can adjust the amount of time the start power is applied. This time is in seconds.

6-3-5-3. Starting Arc Length

In this menu the user can select the desired arc length for the stating time.

6-3-5-4. Start Ramp Time

In this menu the user can select the amount of time required to ramp from the hot start power and arc length to the desired welding wire feed speed
and arc length. This time is in seconds.
OM-254915 Page 36
.
A complete Parts List is available at www.MillerWelds.com
1
1
Lit Indicators
To enable this feature the user must
first access the system menu and
turn the "ALST" feature to "ON". For
1
more information on the system
menu see Section 6-14. For more
information about the hot start func-
tion see section 4-14. Once "ALST"
is turned "ON" the left adjustment
knob is used to cycle through the
hot start parameters.