Table 4-1. Recommended Crater Fill Parameters (Wire Feed Speed/Voltage Or Arc Length/Time)
MIG Setting Example
Wire Speed / 90
Volts / 13.5
Sugges-
Sugges-
ted
Welding
ted
Shield-
Process
Wire
ing
Types
Gases
4XXX
100% Ar
MIG
5XXX
100% Ar
4XXX
100% Ar
Pulse
5XXX
100% Ar

6-19. System Reset

SRST
1
.
A complete Parts List is available at www.MillerWelds.com
Time / 1.0
Wire
1/2 in.
Sizes
3/8 in.
(12.7
(Dia)
99.5 mm)
mm)
0.035 in.
300/22/
300/22/
(0.9 mm)
2.0
2.0
0.047 in.
190/21.5/
190/21.5/
(1.2 mm)
1.15
1.15
0.035 in.
— —
— —
(0.9 mm)
0.047 in.
180/18.5/
180/18.5/
(1.2 mm)
1.25
1.25
0.035 in.
100/35/
100/35/
(0.9 mm)
2.0
2.0
0.047 in.
75/20/1.5
75/20/1.5
(1.2 mm)
0.035 in.
— —
— —
(0.9 mm)
0.047 in.
— —
— —
(1.2 mm)
2
Pulse Setting Example
Wire Speed / 90
Arc Length / 30
Material Thickness
1/4 in.
3/16 in.
1/8 in.
(6.4 mm)
(4.8 mm)
(3.2 mm)
200/12/
200/12/
150/11/
1.25
1.25
1.25
190/21.5/
200/19.5/
215/17/
1.15
1.25
1.0
250/19.5/
250/17/
250/17/
1.25
1.25
1.25
180/18.5/
180/16/
180/16/
1.25
1.25
1.25
100/35/
100/35/
100/35/
2.0
2.0
1.5
75/20/1.5
75//20/1.5
75/20/1.5
120/30/
120/30/
120/30/
1.75
1.5
1.5
105/30/
105/30/
105/30/
1.5
1.05
1.25
1
Time / 1.0
14 ga
16 ga
18 ga
(2.0 mm)
(1.6 mm)
(1.2 mm)
200/11/
— —
— —
0.90
— —
— —
— —
— —
— —
— —
— —
— —
— —
100/20/
100/25/
100/25/
1.5
1.2
1.2
75/20/1.5
75/20/1.0
75/20/1.0
120/30/
120/30/
120/30/
1.0
1.0
1.0
106/30/
105/30/
105/30/
1.0
1.0
0.75
1
Lit Indicators
2
SRST − System Reset
A system reset function is available
to return the machine to the original
factory settings. To access the sys-
tem reset menu turn on the welder.
While the machine is in its startup
routine and the text "MILLERMAT-
IC 350P ALUMINUM" is scrolling
across the screen press and hold
the setup button until the left setup
indicator light illuminates. Next ro-
tate the right adjustment knob until
the Right Display reads "ON". To
trigger the system reset press the
setup button again. System reset is
complete once the "MILLERMATIC
350P
ALUMINUM"
text
scrolled across the screen again. If
the system reset menu is entered
inadvertently and a system reset is
not desired, rotate the right adjust-
ment knob until the Right Display
reads "OFF" and press the setup
button again.
Ref. 242 929-C
OM-254915 Page 51
19 ga
(1.05
mm)
— —
— —
— —
— —
100/35/
1.0
— —
120/30/
1.0
— —
has

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents