Replacement Of J7 Drives With Special Software; Rated Power, Current And Carrier Frequency - YASKAWA VS mini J7 Replacement Instructions Manual

Hide thumbs Also See for VS mini J7:
Table of Contents

Advertisement

6.3

Replacement of J7 Drives with Special Software

The table below gives a reference how to replace J7 drives with special software installed.
The software ID number of the J7 drive that has to be replaced is printed on the name plate.
Software Number
001x, 002x
506x
others
7

Rated Power, Current and Carrier Frequency

Max.
Voltage
Motor
J7 type
class
power
J7xA x
(kW)
0.1
B0P1
0.2
B0P2
Single
0.4
B0P4
phase
0.75
B0P7
200V
1.5
B1P5
0.1
20P1
0.2
20P2
0.4
20P4
3 phase
0.75
20P7
200V
1.5
21P5
2.2
22P2
3.7
23P7
0.2
40P2
0.4
40P4
0.75
40P7
3 phase
1.5
41P5
400V
2.2
42P2
3.0
43P0
3.7
43P7
J7
Description
J7 Standard drive software
High Carrier Frequency
-
J1000
Output
type
power
JA x
(kVA)
BA0001
0.3
BA0002
0.6
BA0003
1.1
BA0006
1.9
BA0010
3.0
2A0001
0.3
2A0002
0.6
2A0004
1.1
2A0006
1.9
2A0010
3.0
2A0012
4.2
2A0020
6.7
4A0001
0.9
4A0002
1.4
4A0004
2.6
4A0005
3.7
4A0007
4.2
4A0009
5.5
4A0011
6.6
VAN-V07007E  [J7→J1000] Replacement Instructions
J1000
Covered by standard software functionality
Covered by standard software functionality
Contact your sales office.
J7
Output
Carrier
Output
current
frequency
power
(A)
(kHz)
(kVA)
0.8
0.3
1.6
0.6
10
3.0
1.1
5.0
1.9
8.0
7.5
3.0
0.8
0.3
1.6
0.6
10
3.0
1.1
5.0
1.9
8.0
3.0
7.5
11.0
4.2
17.5
6.7
1.2
0.9
1.8
1.4
3.4
2.6
7.5
4.8
3.7
5.5
4.2
7.2
5.5
8.6
7.0
J1000
Output
Carrier
current
frequency
(A)
(kHz)
0.8
1.6
10
3.0
5.0
8.0
8
0.8
1.6
10
3.0
5.0
8.0
8
11.0
17.5
1.2
1.8
3.4
8
4.8
5.5
7.2
9.2
15/16

Advertisement

Table of Contents
loading