Nokia NSB-7 Series Service Manual page 166

Transceivers
Table of Contents

Advertisement

NSB-7
Service Software Instructions
Command is used for making call simulation. Function opens Call Simulation dialog.
Dialog mode: modal
Call Simulation dialog has following items:
TX Power Level edit box (ALT+T):
All power levels can be selected. This updates same parameter as TX Power Level in
the RF Controls dialog. Note that TEST value cannot be selected. If TEST value was in
use when Call simulation menu selected, power level is changed to smallest value.
Channel edit box (ALT+C):
This tells the normal operating RF channel number. Normal GSM 1900 channel
numbers can be selected. Same channel is used both for transmission and receiving.
This updates same parameter as Channel in the RF-Controls dialog.
Channel 1,2,3,4,5,6 edit box (ALT+1,2,...):
Channels for monitoring are specified with these six selections. All GSM 1900
channel numbers can be used. If more than one selection has same number, the
monitoring channel list (neighbour list) will have less than 6 selected channels. The
minimum number of monitoring channels is one (all channels have same value).
The monitoring channel can also have same value as normal operating channel.
The first monitoring channel updates same parameter as Monitoring Channel in the
RF-Controls dialog.
Apply button (ALT+A):
Validates and sends entered data to ME.
Page 60
ãNokia Mobile Phones Ltd.
PAMS Technical Documentation
Issue 1 06/00

Advertisement

Table of Contents
loading

Table of Contents