Service Software Instructions
Energy Management Calibration dialog has following items:
Settings group box:
Contains EM calibration setting check boxes:
1. Run battery & charger default values check box (ALT+1):
Runs battery & charger default values to phone when selected
2. Battery voltage check box (ALT+2):
Calibrates battery voltage A/D value.
3. Charger voltage check box (ALT+3):
Calibrates charge voltage A/D value.
4. Battery size check box (ALT+4):
Calibrates battery size A/D value.
5. Battery temperature check box (ALT+5):
Calibrates battery temperature A/D value.
6. Charge current check box (ALT+6):
Calibrates charging current.
Save without confirmation check box (ALT+S):
When selected, all selected calibrations are saved to phone without confirmation,
otherwise user must confirm every A/D value saved to phone. Calibration info is
automatically scrolled during confirmation.
Calibration info list box (ALT+S)
Shows information about current calibrations.
Run button (ENTER):
All selected settings are executed.
Close button (ESC):
Dialog is closed.