Cable Glands - Siemens SIMOTICS SD 1LE5 Operating Instructions Manual

Low-voltage motors
Table of Contents

Advertisement

B.1.4

Cable glands

Note
Avoid damaging the cable jacket.
Adapt the tightening torques to the cable jacket materials.
You should refer to the table in order to find the correct tightening torque for any metal and
plastic cable glands that are to be mounted directly on the machine, as well as for any other
screw-type connections (such as adapters).
Table B- 4
Tightening torques for cable glands
M 12 x 1.5
M 16 x 1.5
M 20 x 1.5
M 25 x 1.5
M 32 x 1.5
M 40 x 1.5
M 50 x 1.5
M 63 x 1.5
M 63 x 1.5
M 75 x 1.5
M 75 x 1.5
M 80 x 2.0
M 80 x 2.0
1LE5, 1PC4 shaft height 315/355
Operating Instructions, 10/2020, A5E41454666A
Metal
Plastic
± 10%
± 10%
Nm
Nm
8
1.5
10
12
18
20
80
Clamping range [mm]
Standard
-30 °C ... 100 °C
3.0 ... 7.0
2
4.5 ... 10.0
4
7.0 ... 13.0
9.0 ... 17.0
6
11.0 ... 21.0
19.0 ... 28.0
26.0 ... 35.0
34.0 ... 45.0
42.0 ... 54.0
54.0 ... 58.0
59.0 ... 63.0
58.0 ... 64.0
63.0 ... 70.0
Technical specifications
B.1 Tightening torques
O ring
Cord ∅
mm
2
127