6 Commissioning the Router Kit WLAN / LAN
6.4 Setting the IP address of the SCALANCE W774-1
109. Set the check mark for "Assign IP parameters" and set the following properties:
– IP address: 192.168.1.20
– Important: Set the check mark for "Use router".
– As IP address, enter the IP address of the LTE module (here: 192.168.1.1).
Figure 6-20
110. Click the "Load" button
111. Close the PST.
Application example for SIMOTICS CONNECT 400 - Router KitInbetriebnahme- und Montagehandbuch
You can specify any IP address. It should be in the same address range as the IP
address of the LTE module.
Make sure that you do not assign the same IP address as for the PC (described under
"Setting up interfaces (page 71)").
Entering the Ind. Ethernet interface field
and confirm the subsequent dialog with "Yes".