Omron H8GN Manual page 9

Preset counter/timer
Hide thumbs Also See for H8GN:
Table of Contents

Advertisement

H8GN
2. Using the H8GN as a Timer
Typical Application Examples
1. Changing Set Values
Set value and selections in each
display can be changed by pressing
the
and
Keys.
2. Display
No. 1 Display
No. 2 Display
Typical Application Examples
Time range
0.0 to 999.9 s
Timer mode
DOWN (remaining time)
Output mode
A mode
Output time
Hold
Input signal width
20 ms
Setup Procedure
Power ON
Operation Level
Initial Setting Level
Set Counter/Timer
Use the
Keys to select the timer
selection
function.
Use the
Set time range
Keys to set the time range to
999.9 s
Check timer mode
Use the
Keys to set the timer mode to
remaining time.
Check output mode
Check the output mode.
Check output time
Check the output time.
Check input signal
Check the input signal width.
width
Operation Level
Use the
Set SV
Keys to set the SV to 10.0.
Press the
Reset PV
Start operation
Confirming Set Values
Set values are effective two seconds after key operation is stopped or when the
or
Key is pressed.
Power ON
Present value (PV)/
set value (SV)
and
Function:
and
Time range:
and
Timer mode:
Output mode:
Output time:
Input signal width:
and
PV/SV:
Key.
PV:
Operate
H8GN
Press the Level Key for at
least 3 s. Operation stops.
Press the Level Key for at
least 1 s. Operation starts.
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H8gn-adH8gn-ad h8gn-ad-flkH8gn seriesH8gn-ad-flk

Table of Contents