Omron H8GN Manual page 13

Preset counter/timer
Hide thumbs Also See for H8GN:
Table of Contents

Advertisement

H8GN
Example: To have a display of
puts 25 pulses when the object has been moved forward 0.5 m,
perform the following steps.
1. Set the decimal point position to before the second-last digit.
2. Set the prescale value to 0.02 (0.5
(edge)
12. Input Signal Edge
The input signal edge will be displayed only when the "input
mode" at the initial setting level has been set to increment or
decrement.
Switches the CP1 input edge when the H8GN is used as an in-
crementing or decrementing counter. In the counter increment or
decrement modes, CP2 will function as the gate input and CP1
counting will be prohibited while CP2 is ON.
Refer to Input/Output Modes and Count Values on page
NO TAG for information on input mode operations.
13. Move to Advanced Function Setting Level
This will be displayed only when the "initial setting/commu-
nications protection" in protect level is set to 0.
This setting enables the advanced function settings to utilize the
counter/timer functions to the maximum. To move to the ad-
vanced function setting level, enter the password (–169) from
the initial setting level.
.
m for a system that out-
25).
25 pulses
Encoder
(amoU)
H8GN
15