Technical information

Deep cleaning the machine

PH01 and PH02 have a 'self cleaning' cycle built in. This is to reduce limescale build up. In
normal use the machine will show an alert when it needs to carry out a Deep clean cycle.
If connected to the Dyson Link app, you will receive a notification message. If not using the
Dyson Link App, the LCD screen on the machine will alert you and the Deep clean cycle
button will light up. To cancel the Deep clean cycle at any point, press and hold the Deep
clean cycle button for five seconds.
Important: do not turn off or unplug the machine as the cleaning instructions will appear
on the LCD screen.
Press the Deep clean cycle button on
the front of your machine and your
instructions will be shown on the LCD
screen.
Put the shrouds to one side
Remove the evaporator
as you carry out the Deep
from your
clean cycle.
machine, place it in the
water tank
MAX level
and refit the cap.
3
3
3
3
Push down the Water tank release buttons
on the sides of your machine.
Slide the water tank out of your machine
and unclip the cap.
Carry the water tank by its
handle to the tap.
Remove the cap and
evaporator.
Fill the water tank halfway to
the Max level with cold tap
water.
06
Technical information
Deep cleaning the machine
Measure out 150g of citric
Agitate gently until all the
acid and place it in the
citric acid has dissolved.
water tank.
Replace the cap and
secure the cap clips
in place. Wipe off any
excess water to avoid
drips.
Slide the water tank into your machine until
it clicks securely in place. When prompted
by the LCD screen, press the Deep clean
cycle button. The Deep clean cycle will start
and the LCD screen will show a countdown
timer.
MAX level
MAX level
MAX level
Place the evaporator in
the water tank. Fill the
water tank to the Max
level with cold tap water.
MAX level
When the LCD screen shows the Deep clean
cycle is complete, push down the water
tank release buttons on the sides of your
machine. Slide the water tank out of your
machine. Carry the water tank by its handle
to the tap.