Product overview
Features and benefits
Sensor detects and display pollutants and humidity levels
A unique algorithm processes input from each sensor and
activates the machine, to capture pollutants, humidity, and
project cleaner air.
Captures gases and ultra fine particles
The sealed filtration system combines an activates
carbon filter to remove gases and a sealed HEPA
filter to capture 99.95% of ultra fine particles.
PH01 machine comes with Combination filters.
PH02 comes with permanent Cryptomic filters
and Combination filters.
Anti-bacterial evaporator
Silver strands are woven into 3D air mesh of 6mm
intervals.
They help prevent bacteria from growing on the
evaporator.
Destroys potentially harmful bacteria
Dyson Ultraviolet Cleanse technology exposes
every drop of water to an ultraviolet light. This
kills 99.9% of bacteria.
Reflective PTEE tube
Made from a highly reflective material. It
mirrors UV light up and down the tube, to
kill bacteria.
01
Wrong PSU
Broken pump column
Tank missing static
02
Product overview

Display error symbols

The UI screen shows different error icons according to the machine's status. Many of these are temporary
or can be corrected by carring out a hard reset and/or a software update. To hard reset, switch off the
machine and unplug the mains supply for 20 secs, then plug the machine back in and switch it back on.
Wrong PSU
Broken pump column
Drip tray overflow
Too cold
Clean cycle post clean –
complete
Too cold
Pump rotor failure
Not complete
Tank empty static
1. Temp Sensor fault
2. Humidity Sensor fault
3. Air Quality (AQ) Sensor fault
4. Wrong Power Supply Unit (PSU) inserted/PSU fault
5. Fault. Carry out a Hard reset. If this doesn't fix the issue check
'Fault codes' (pages 5 - 6)
Drip tray overflow
6. Broken pump column. Replace the Pump column assembly
7. Drip tray overflow. Carry out a deep clean cycle (pages 6 -7).
If this doesn't fix the issue check 'Fault codes' (pages 5 - 6)
Pump rotor failure
8. Too cold. Displayed when ambient temperature drops
Clean cycle – insert tank (takeover)
below 5
c and there is water in the tank
o
9. Pump rotor failure. Replace the Pump column assembly
10. Clean cycle not complete. Repeat the clean cycle (pages 6
-7) and allow to run until completion
11. Water tank empty. If not empty, replace the Pump column
assembly