Reel Circuit Testing − Manifold Relief Valve (SV) Pressure Test
g345058
Reelmaster
®
3100-D/3105-D
20252SL Rev A
Model 03171 (shown)
Test the performance of the mow control manifold relief valve (SV) to make
sure that the maximum amount of fluid is available to the cutting unit motors up
to the set relief pressure. This test also ensures that pump (P1) is capable of
generating enough pressure to open a properly functioning relief valve.
Special Equipment Required:
•
Flow Meter with Pressure Gauge that has at least a 45 LPM (12 GPM)
capacity
•
Phototach (non−contact tachometer)
Figure 52
Page 5–49
Hydraulic System: Testing