Worcester Greenstar Condensfit II Installation Instructions Manual page 20

Wall mounted gas condensing appliance flue 60/100 horizontal 1050mm fixed flue
Hide thumbs Also See for Greenstar Condensfit II:
Table of Contents

Advertisement

Plume management system
Terminal elbow fitting
Terminal elbow ( figure 47)
▶ Remove and retain the retaining screws [2] and discard the terminal
end [3].
▶ Fit the terminal elbow [1] to the terminal outlet and set the rotation of
the terminal elbow depending on the plume installation option
required.
▶ Secure the terminal end [1] with the screws [2] removed previously.
1
3
Fig. 47 Plume management terminal elbow
Extension fitting
Extension tube ( figure 48)
▶ Push the extension tube [2] fully into the terminal elbow [3], then
withdraw the tube approximately 10mm to allow for expansion.
▶ Secure the extension [2] to the wall with the support clamp and
screws provided [1].
Extension tube with additional elbow (45° elbow example  figure 48)
▶ Push the extension tube [2] fully into the terminal elbow [3], then
withdraw the tube approximately 10mm to allow for expansion.
▶ Secure the extension [2] to the wall with the support clamp and
screws provided [1].
▶ Push the 45° elbow [4] fully into the extension tube [2], the stop tabs
set the depth and allow for expansion.
▶ Further extensions are fitted in the same way as previously
described.
1
2
3
Fig. 48 Plume extension fitting
20
2
±80°
2
4
2
1
±80°
Discharge elbow fitting
Outlet assembly (vertical orientation figure 49)
▶ Secure the extension [4] to the wall with the support clamp and
screws provided [3].
▶ Push the outlet assembly elbow [1] fully into the extension tube [4],
the stop tabs set the depth and allow for expansion.
▶ Rotate the outlet assembly [1] to the required direction permitted.
▶ Secure the outlet assembly elbow [1]to the extension [4] with the
self-tapping screw [2] provided.
Outlet assembly (angled orientation figure 49)
▶ Secure the extension [4] to the wall with the support clamp and
screws provided [3].
▶ Push the outlet assembly elbow [1] fully into the extension tube [4],
the stop tabs set the depth and allow for expansion.
▶ Rotate the outlet assembly elbow [1] to the required direction
permitted.
▶ Secure the outlet assembly elbow [1]to the extension [4] with the
self-tapping screw [2] provided.
±45°
1
2
4
3
Fig. 49 Fitting the discharge elbow
Greenstar Condensfit II – 6 720 874 391 (2019/04)
1
4
3
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

7 733 600 2987 716 191 086

Table of Contents