Turret Flue Adaptor Installation; Vertical Flue Adaptor Installation; Flue Joint Connection Examples - Worcester Greenstar Condensfit II Installation Instructions Manual

Wall mounted gas condensing appliance flue 60/100 horizontal 1050mm fixed flue
Hide thumbs Also See for Greenstar Condensfit II:
Table of Contents

Advertisement

1
5
Fig. 20 Fixed length flue through the wall
[A]
Wall
[1]
Inner wall seal
[2]
Outer wall seal
[3]
Terminal
[4]
Fixed flue
[5]
Flue hole
4.2

Turret flue adaptor installation

The turret is fixed by 3 screws to the top of Greenstar wall mounted
condensing gas appliance.
▶ Some models use an additional 3 screws for the appliance flue
connector.
– Refer to relevant Installation and maintenance Instructions.
▶ Remove the 3 appropriate screws securing the flue outlet to the
appliance.
▶ Align the turret to the appliance flue outlet with the flat [2] facing to
the rear of the appliance.
▶ Fit to the appliance using the 3 removed previously (1) and secure
the turret in position.
Fig. 21 Adaptor installation
4.3

Vertical flue adaptor installation

The vertical adaptor is fixed by three screws to the top of the Greenstar
wall mounted condensing gas appliance.
▶ Some models use an additional three screws for the appliance flue
connector.
– Refer to relevant Installation and maintenance Instructions.
▶ Remove the three appropriate screws securing the flue outlet to the
appliance and discard.
▶ Align the high level horizontal flue adaptor to the appliance flue outlet
with the flat [2] facing to the rear of the appliance.
Greenstar Condensfit II – 6 720 874 391 (2019/04)
2
3
4
1
2
▶ Fit to the appliance using the three longer screws (1) provided with
the high level horizontal flue adaptor.
Fig. 22 Adaptor installation
4.4

Flue joint connection examples

CAUTION:
Damage to flue system!
▶ Take care when drilling fixing points in the outer flue tube, do not to
drill into the inner tube.
Connection to the flue adaptor, Greenstar wall mounted condensing
gas appliances
Flue extension and 90° elbow ( figure 23)
▶ Fit the extension piece [4] into the flue adaptor [5] and drill pilot hole
through the outer flue tube of extension [4] and flue adaptor [5].
▶ Secure with the screw provided in the high level horizontal flue
adaptor kit.
▶ Fit the 90° elbow [1] firmly into the extension piece [4] use the
silicone grease provided with the extension kit.
▶ Drill two pilot holes, through the outer flue tube of extension [4] and
90° elbow [1].
▶ Secure the 90° elbow [1] into the extension piece [4] with the screws
[3] provided with the extension kit.
90° elbow ( figure 23)
▶ Fit the 90° elbow [2] firmly into the flue adaptor [5] and drill pilot
hole through the flue adaptor [5] and 90° elbow [2].
▶ Secure with the screw provided.
1
3
Fig. 23 Connection to the flue adaptor examples
Installation
1
2
2
3
4
5
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

7 733 600 2987 716 191 086

Table of Contents