Plume management system
5.2.7
Plume management kit under a balcony/overhang example
The extension pipe [2] must be supported as close to the 90° elbow [3]
and before the end of the balcony/overhang to provide adequate
support.
▶ If the supplied brackets are not long enough then third party 60mm
pipe brackets [7] can be used.
The shaded area X is the exclusion zone for plume discharge. The
discharge must be outside this zone.
2,000mm
1,000mm
52mm
104mm
100mm
m m
≥ 5 0 0
X
Fig. 36 Under a balcony/overhang option
16
1
3
2
4
7
3°
0010013701-001
5.2.8
Extended plume management kit under a balcony/
overhang example
The shaded area X is the exclusion zone for plume discharge. The
discharge must be outside this zone.
2,000mm
1,000mm
52mm
104mm
100mm
≥140mm
m m
0 0
≥ 5
X
Fig. 37 Extended under a balcony/overhang option
Greenstar Condensfit II – 6 720 874 391 (2019/04)
1
3
4
2
5
3°