Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
Premium spas are equipped with the drain arranged as in
1-1a-1b-1c-1d-1e-1f-1g, part.A.
The customer must make provisions for a ground drainage
point of suitable dimensions and that can be inspected for any
cleaning that may be required.
ATTENTION: Before preparing the ground drainage
point, consult the local authority for the regulations
that control the drainage of chemically treated water.
Premium spas are equipped with the drain arranged as in
(1-1a-1b-1c-1d-1e-1f-1g, part.A).
For periodic emptying of the spa you can connect a rubber hose
to the drain valve (1-1a-1b-1c-1d-1e-1f-1g, part.A).
NOTE: To open the valve, turn the ring nut counter-clockwise and
pull.
If you decide to attach the spa to the drain, it is advisable to connect
upstream from the valve (for greater flow capacity) and to install a
shutter valve near the drain in an accessible area (
1d-1e-1f-1g, detail A1).
According to the type of installation chosen the ground drai-
nage point will then be put into position. The Premium spas can
be installed in a variety of ways:
- Free standing on the floor or on a specifically prepared base
(
5).
- Semi-built in, so that only the base of the spa is built-in and
therefore the side cover panels remain free (
it is appropriate to prepare some removable under-frames (in
marine plywood, etc.) that, besides aesthetically completing in-
stallation, allow the panels to be removed more easily.
In any case you will need to provide a support base that is su-
itable for the selected model, taking into consideration the data
contained in the table "Weights".
In the case of intermediate flooring, terraces, roofs
or other similar structures, consult a building engi-
neer.
(
2) The support base must be flat and level in
order to provide uniform support for the weight of
the spa. Otherwise the front panels and/or metha-
crylate shell could be damaged: this damage is not
covered by the warranty.
You can use a garden hose to fill the spa.
If the spa is connected, for periodic filling, to the
mains system that supplies drinking water, this
connection must be carried out in compliance with
the EN1717 norm, using "AA", "AB" or "AD" anti-pol-
lution protection procedures. For further informa-
tion, we recommend you contact your water supply
company and/or your plumber.
For indoor installation, it is necessary to remember that water
evaporation from the spa (especially where high temperatures
are involved) can cause very high levels of humidity. Natural or
forced ventilation helps to maintain personal comfort and redu-
ce damage to the building due to humidity.
Jacuzzi Europe refuses all responsibility for any damage caused
by excessive humidity or by overflowing water. Consult a specia-
list for indoor installation.
Remember that it is compulsory to install a multiple-pole
section switch with characteristics that are not less than the
ones given in the chapter "Electrical safety" and
The installer must use cables with an adequate cross-section,
protected by a sheath and/or with tubes or ducts, with characte-
ristics not inferior to type H 05 VV-F.
The entry of cables into the mini-pool up to the electrical box
(
3) must be provided at point B or B1, depending on the cu-
stomer's installation needs.
Note: The lead sections must take account not only the sy-
stems absorption but also the cable path and the distances,
the chosen protection systems and the specific regulations
for fixed electrical systems in force in the country where the
1-1a-1b-1c-
spa is installed.
The installer must comply with the above regulations, and
also use watertight connectors at connection points. He
must also guarantee compliance with the specific current
standards for systems in the country in which the spa is in-
stalled.
It is mandatory to comply with this instruction. Any other procedu-
re is prohibited.
6). In this case,

Electrical safety

The Premium spas are safe products, manufactured in com EN
60335-1, EN 60335-2-60, EN 12764 and tested during pro-
duction to ensure user safety.
Installation must be carried out by qualified and authorized
personnel, in compliance with current national provisions.
The Premium spas are class "I" appliances and therefore they
must be permanently connected, without any intermediate
connections, to the electrical system and to the protection sy-
stem (earth system).
18
It is the responsibility of the installer to select mate-
rials based on their intended use, to carry out work
properly, to check the condition of the system that
the unit will be connected to and that it ensures sa-
fety of use also concerning maintenance work and
the possibility to examine the system.
The electrical system of the building must be pro-
vided with a 0.03A differential switch and with an
efficient protection (earth) circuit.
Check for proper operation of the differential swi-
tch by pressing the TEST button, which should trip.
Parts incorporating electrical components, except
remote control devices, must be located or fixed so
that they cannot fall into the spa.
3.

Advertisement

Table of Contents
loading

This manual is also suitable for:

J-315J-325J-335J-345J-355J-365 ... Show all

Table of Contents